Comparable performance of 1,5-anhydroglucitol and continuous glucose monitoring in detecting subclinical atherosclerosis in elderly patients with type 2 diabetes
Hang Su, Jiaying Ni, Jingyi Lu, Wei Lu, Wei Zhu, Yufei Wang, Xiaojing Ma, Danfeng Peng,
Shanghai Jiao Tong University · Shanghai Sixth People's Hospital
Key points
From the paper's conclusion- In older adults with type 2 diabetes, 1,5-AG demonstrated a performance comparable to CGM for detecting abnormal CIMT, supporting its potential as a clinical biomarker for identifying subclinical atherosclerosis.
Abstract
The comparison between conventional glycemic markers and continuous glucose monitoring (CGM) in relation to adverse outcomes in the elderly with type 2 diabetes remains unclear. We aimed to assess associations of 1,5-anhydroglucitol (1,5-AG) and CGM metrics with carotid intima-media thickness (CIMT) as a surrogate of cardiovascular disease. The study included 2509 adults aged ≥ 60 years with type 2 diabetes. CIMT was measured by high-resolution ultrasonography, with abnormal CIMT defined as a mean thickness of ≥ 1.0 mm. Time in range (TIR), mean sensor glucose (MSG), time above range (TAR, > 10.0 mmol/L), standard deviation (SD), and coefficient of variation (CV) were calculated from CGM data. The median serum 1,5-AG was 3.9 (2.0, 8.0) μg/mL, and the prevalence of abnormal CIMT was 44.2% (n = 1,109). The prevalence of abnormal CIMT decreased across ascending 1,5-AG categories (P for trend < 0.01). In the fully adjusted model, each 1-standard deviation decrease in 1,5-AG conferred 10% higher odds of abnormal CIMT. Compared with 1,5-AG ≥ 10.0 μg/mL, 1,5-AG < 6.0 μg/mL was associated with an odds ratio of 1.25 (95% CI 1.00–1.55) for abnormal CIMT. Among CGM metrics, TIR, MSG, and TAR > 10.0, but not CV or SD, were significantly associated with abnormal CIMT. The C-statistics for 1,5-AG in predicting abnormal CIMT were comparable to those for TIR, MSG, and TAR >10.0 (all P > 0.05). In older adults with type 2 diabetes, 1,5-AG demonstrated a performance comparable to CGM for detecting abnormal CIMT, supporting its potential as a clinical biomarker for identifying subclinical atherosclerosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 1,5‐Anhydroglucitol and Time in Range as Complementary Markers for Diabetic Retinopathy in Type 2 DiabetesDiabetes/Metabolism Research and Reviews · 2026
- Glycemic variability and coronary plaque progression in statin-treated type 2 diabetic patients with coronary artery disease: a prespecified sub-analysis of the OPTIMAL Randomized Controlled TrialEuropean Heart Journal · 2026
- Lack of Association Between Hemoglobin A1c and Continuous Glucose Monitor Metrics Among Individuals with Prediabetes and NormoglycemiaDiabetes Technology & Therapeutics · 2025
- Consumer continuous glucose monitoring uncovers hidden metabolic risk in free-living adults without diabetesmedRxiv · 2026
- Continuous Glucose Monitoring-Derived Glycemic Phenotypes Reflect Metabolic Heterogeneity Linked to Advanced Cardiovascular-Kidney-Metabolic Syndrome in Older Adults With Type 2 Diabetes.Journal of diabetes · 2026
- Association of HbA1c and an updated glucose management indicator (uGMI) with incident diabetic retinopathy in adults with type 1 diabetes: a longitudinal studyDiabetologia · 2025