Department of Nuclear Medicine, Xijing Hospital, Fourth Military Medical University, 127 West Changle Road, Xi'an, 710032, China. · Key Laboratory of Radiopharmaceuticals of Ministry of Education, College of Chemistry, NMPA Key Laboratory for Research and Evaluation of Radiopharmaceuticals (National Medical Products Administration), Beijing Normal University, Beijing, 100875, China. zhjunbo@bnu.edu.cn.

Trial · n=20

Key points

From the paper's conclusion
  • 99mTc-CN7DG is a safe SPECT tracer and can serve as a complementary approach to conventional imaging when performed with quantitative SPECT/CT, especially for CNS tumor patients with false-negative 18F-FDG results or contraindications to MRI.

Abstract

BACKGROUND: To evaluate the novel SPECT tracer 99mTc-CN7DG in a first-in-human clinical trial and assess its diagnostic value for central nervous system (CNS) tumors. METHODS: Five Healthy volunteers were enrolled to assess the safety, biodistribution, and dosimetry of 99mTc-CN7DG. Subsequently, we prospectively enrolled 20 patients suspected a CNS tumor underwent MR, 18F-FDG PET/CT, and 99mTc-CN7DG quantitative SPECT/CT. The number of lesions and semi-quantitative parameters including the SUVmax, SUVmean, SUVmin, and lesion-to-background ratio (LBR) were measured. RESULTS: No adverse reactions were observed in any volunteers or patients after the injection of 99mTc-CN7DG. The mean whole-body effective dose estimated was 5.24 × 10⁻³ mSv/MBq. A total of 45 lesions were analyzed. Based on patient analysis, the detection rate was 90.0% (18/20) for 99mTc-CN7DG and 45.0% (9/20) for 18F-FDG. 99mTc-CN7DG quantitative SPECT/CT demonstrated superior lesion detection to 18F-FDG PET/CT (41 vs. 21, P < 0.0001), achieving a 44.4% reduction in the false-negative rate (sensitivity and accuracy: 0.911 vs. 0.467). Furthermore, it yielded significantly higher target-to-background contrast (LBRmax: 14.24 ± 9.44 vs. 1.15 ± 0.41; P < 0.0001). The Ki-67 index showed a correlation with both the lesional 18F-FDG PET/CT SUVmax (r = 0.72, P < 0.05) and LBRmax (r = 0.71, P < 0.05). Based on lesion type analysis, 99mTc-CN7DG demonstrated superior sensitivity for gliomas (5/5 patients, 8/8 lesions) and brain metastasis (99mTc-CN7DG detecting 2 more patients and 10 more lesions than 18F-FDG). In contrast, 18F-FDG was the only tracer that successfully identified lymphoma cases (1/1 patient, 3/3 lesions). CONCLUSIONS: 99mTc-CN7DG is a safe SPECT tracer and can serve as a complementary approach to conventional imaging when performed with quantitative SPECT/CT, especially for CNS tumor patients with false-negative 18F-FDG results or contraindications to MRI.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers