Slovak cross-cultural adaptation of the Alarm Fatigue Assessment Questionnaire.
Łukasz Rypicz, Martin Bereta, Olexander Dobrovanov, Olga Fedorowicz, Mária Šupínová
Division of Public Health, Department of Public Health, Wroclaw Medical University, Wroclaw, Poland. lukasz.rypicz@umw.edu.pl. · Catholic University in Ružomberok, Ružomberok, Slovakia.
Key points
From the paper's conclusion- The Slovak adaptation of the Alarm Fatigue Assessment Questionnaire (AFAQ) demonstrated acceptable internal consistency and preliminary evidence of structural validity in the studied sample. However, the factorial structure showed only partial support, and several items demonstrated limited psychometric performance. Therefore, the Slovak AFAQ should currently be considered a preliminary cross-cultural adaptation requiring further validation in more diverse healthcare populations and clinical settings before broader application.
Abstract
BACKGROUND: Alarm fatigue is a significant issue in intensive care settings, where frequent alarms from medical equipment may overwhelm healthcare workers. This can lead to desensitization, delayed responses, and risks to patient safety. There is a lack of validated tools for assessing alarm fatigue in Slovak healthcare environments. The aim of this study was to adapt the Alarm Fatigue Assessment Questionnaire (AFAQ) to Slovak conditions and evaluate its psychometric properties. METHODS: A cross-sectional online survey was conducted between June and July 2023 among 379 Slovak healthcare professionals working with electromedical devices. The Polish version of the AFAQ was translated and culturally adapted into Slovak following established international guidelines. Reliability was assessed using Cronbach's alpha. Confirmatory factor analysis (CFA) was performed to test the scale's structure. Floor and ceiling effects were also analyzed to evaluate item performance. RESULTS: The Slovak version of the AFAQ showed acceptable internal consistency with a Cronbach's alpha of 0.795. CFA supported a unidimensional structure after minor modifications (RMSEA = 0.058; SRMR = 0.086). CONCLUSIONS: The Slovak adaptation of the Alarm Fatigue Assessment Questionnaire (AFAQ) demonstrated acceptable internal consistency and preliminary evidence of structural validity in the studied sample. However, the factorial structure showed only partial support, and several items demonstrated limited psychometric performance. Therefore, the Slovak AFAQ should currently be considered a preliminary cross-cultural adaptation requiring further validation in more diverse healthcare populations and clinical settings before broader application. CLINICAL TRIAL NUMBER: Not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Alarm Fatigue and Nursing Performance Among Hospital Nurses in South Korea: A Cross-Sectional Study of Indirect Association Through Perceived Stress and Moderating Role of Patient Safety CultureHealthcare · 2026
- Polish Cross-Cultural Adaptation and Preliminary Psychometric Evaluation of the Left Ventricular Assist Device Self-Care Behaviour Scale: A Cross-Sectional Study.Journal of clinical nursing · 2026
- Validity and Reliability of the Turkish IPREA-18: A Psychometric Study in Intensive Care Unit Patients.Journal of nursing measurement · 2026
- Severity and Associated Factors of Alarm Fatigue Among Intensive Care Unit Nurses: A Systematic Review and Meta-Analysis.Nursing in critical care · 2026
- Associations between alarm fatigue and burnout dimensions among intensive care unit nurses: a systematic review and meta-analysisFrontiers in Public Health · 2026
- Cross-Cultural Adaptation and Psychometric Evaluation of the Patient Safety Care Activity Scale in Turkish.Journal of nursing measurement · 2026