BMC medical informatics and decision making

AI safety evaluation in an underrepresented population: real-world performance of clinical decision support and frontier language models on Medicaid patient messaging triage.

Sanjay Basu, Sadiq Y Patel, Parth Sheth, Bernardo Arevalo, Jeremy Schifberg, John Morgan, Rajaie Batniji

University of California, San Francisco, San Francisco, CA, USA. sanjay.basu@ucsf.edu. · University of Pennsylvania, Philadelphia, PA, USA.

Observational

Key points

From the paper's conclusion
  • No evaluated tool or combination was sufficiently accurate to enable physician-unassisted triage in this setting. Two configurations met the pre-specified sensitivity-floor target under clinician review of flagged messages, following the classical clinical-screening pattern.

Abstract

BACKGROUND: Studies of artificial intelligence tools used in patient triage have largely involved academic medical center cohorts, scripted patient-actor scenarios, or knowledge benchmarks. Populations that may rely on such tools due to constrained access to in-person care, including Medicaid patients, have been less fully evaluated. OBJECTIVE: To compare combinations of safety guardrails added to artificial intelligence tools for triage of patient-initiated text messages in a multi-state Medicaid population. METHODS: Retrospective evaluation of 2000 messages from Medicaid patients across three U.S. states (Virginia, Washington, Ohio) during January 2023 through November 2025. Three physicians independently adjudicated each message under blinded review; disagreements were resolved by majority and a senior-physician arbiter. Tools included a deployed decision support system with a Conservative Q-Learning controller, supervised baselines (XGBoost+sentence-BERT, logistic regression, rule-based guardrails), and frontier large language models (Claude Opus 4.7, GPT-5.5, Gemini 3.1 Pro, each with and without retrieval-augmented generation). Combinations spanned single tools, ensembles, cascades, multi-model consensus rules, and four-component guardrail compositions identified by a structured literature review. Thresholds and Platt calibration were fit on a held-out validation split and frozen before the test pass. Two pre-specified targets: an autonomous (physician-unassisted) triage benchmark of sensitivity and specificity both 0.80 or higher; and a sensitivity-floor target of 0.80 to 0.95 with clinician review of flagged messages. RESULTS: Real-world messages had lower reading level (grade 4.6 versus 5.8) and more colloquialisms (59.1% versus 19.5%) than physician-scripted scenarios. Hazard prevalence on blinded physician review was 8.2% (165 of 2000). Two configurations met the sensitivity-floor target: a high-recall first-stage screen (sensitivity 0.855; 12.0 missed hazards and 729 alerts per 1,000 messages) and a disagreement-stratified clinician-review workflow (sensitivity 0.939; 5.0 missed hazards and 878 alerts per 1,000 messages). No configuration met the autonomous benchmark; sensitivity and specificity reached 0.594 and 0.592 for the best balanced single tool, 0.685 and 0.575 for the best balanced ensemble, and 0.297 and 0.874 for the highest-specificity cascade. CONCLUSIONS: No evaluated tool or combination was sufficiently accurate to enable physician-unassisted triage in this setting. Two configurations met the pre-specified sensitivity-floor target under clinician review of flagged messages, following the classical clinical-screening pattern.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers