Stability, survival and costs of vacuum-formed retainers versus bonded lingual braided rectangular and multistranded round wire retainers in the mandible of orthodontic patients over a two-year period
Silvija Kanizaj Ugrin, Jeta Kiseri Kubati, Emina Čirgić, Paris Simeon, Stjepan Špalj
University of Zagreb · University for Business and Technology
Key points
From the paper's conclusion- To assess the efficacy in relation to costs of three retention techniques: vacuum-formed retainers (VFR) with lingual-bonded braided and multistranded wire retainers in the mandible.
Abstract
BACKGROUND: To assess the efficacy in relation to costs of three retention techniques: vacuum-formed retainers (VFR) with lingual-bonded braided and multistranded wire retainers in the mandible. METHODS: A total of 93 participants, aged 12–21 years at the start of the retention phase (median age: 16 years; 66% females) were assessed. Analysis included retainer survival rate, costs associated with retention procedures, degree of mandibular incisor irregularity, and patient satisfaction. The cost-minimization analysis accounted for direct costs (material and production expenses, utility costs, and chair time based on personnel wages). RESULTS: The survival rate of retainers was 74% for VFR, 71% for rectangular wire retainers, and 62% for round wire retainers, with no significant differences among groups. Incisor alignment relapse was minimal overall but was highest in the VFR group compared to both wire types (p < 0.001). No differences in satisfaction were observed between groups. However, total retention costs varied significantly (p = 0.001), with the VFR group showing the lowest median cost (34.39 €) and rectangular wire group the highest (44.61 €). CONCLUSION: The retainers demonstrated similar survival rates, provided equal patient satisfaction, and maintained alignment effectively, with differences in stability remaining below evidence-based thresholds. However, VFR incurred 21–23% lower costs than fixed retainers, a finding with practical relevance for public or resource-limited settings. TRIAL REGISTRATION: ClinicalTrials.gov, NCT05121220. Registered 02 October 2021.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Mechanical Characteristics of Three Different Types of Wires for Bonded Lingual Retainer Fabrication.Journal of dentistry (Shiraz, Iran) · 2026
- Retention Wear Protocols and Short- to Medium-Term Post-Treatment Stability Following Clear Aligner and Fixed Appliance Therapy: A Systematic ReviewOral · 2026
- Round versus Locator Attachment Effect on The Retention Forces of Implant-Supported Maxillary Overdentures. A Comparative In Vitro StudyRazi Medical Journal · 2026
- A randomised controlled trial comparing thermoformed and 3D-printed retainers in young adults: evaluation of surface roughness, surface morphology, and mechanical properties.Clinical oral investigations · 2026
- Retention characteristics of individually milled bar systems with customized patrices: An in vitro comparison of electroplated and friction-based retention concepts.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Patient experiences with orthodontic retention and retainers: A scoping reviewAmerican Journal of Orthodontics and Dentofacial Orthopedics · 2026