The accuracy of reconstruction of orbital wall fractures using prebent mesh versus patient specific implants: a randomized clinical trial
Mona S. Sheta, Wesam H. Elsaadany
Tanta University
Key points
From the paper's conclusion- Patient-specific titanium implants significantly improved the accuracy of orbital volume restoration, particularly in cases involving large defects.
Abstract
BACKGROUND: Repairing fractures of the orbital wall and floor remains a complex challenge due to the intricate anatomy of the orbit and the limited visibility during surgery. With the advancement of digital technologies, tools such as DICOM (Digital Imaging and Communications in Medicine) now allow the creation of virtual mirrored models of the unaffected orbit, which can greatly assist in surgical planning and reconstruction. This study aimed to evaluate the accuracy of orbital wall reconstruction using patient-specific implants (PSIs) versus prebent titanium mesh. MATERIALS AND METHODS: A single-blind randomized controlled clinical trial was carried out on 28 patients with unilateral orbital fractures, who were randomly divided into two equal groups. Group I underwent orbital wall reconstruction using prebent titanium mesh, while Group II received titanium PSIs. Clinical and radiographic evaluations were carried out at 1 week, 1 month, and 3 months postoperatively to evaluate enophthalmos, ocular motility, diplopia, and the precision of orbital volume restoration. RESULTS: The mean postoperative orbital volume was 27.48 ± 1.324 cm³ in Group I and 25.62 ± 1.492 cm³ in Group II. The difference in orbital volume between the reconstructed and intact orbit was significantly smaller in the PSI group (0.6543 ± 0.2767 cm³) compared to the pre-bent mesh group (1.666 ± 0.3884 cm³; p < 0.05). CONCLUSION: Patient-specific titanium implants significantly improved the accuracy of orbital volume restoration, particularly in cases involving large defects. Compared to pre-bent titanium mesh, PSIs reduced the need for revision surgery and offered superior volumetric outcomes. In contrast, prebent titanium mesh still provided satisfactory results for isolated single wall fractures and is likely to be cost-effective. TRIAL REGISTRATION: This trial was retrospectively registered at ClinicalTrials.gov on March 05, 2024, under the registration number NCT06294535.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Classical vs. Customized Post-Traumatic Orbital Reconstruction with 'In-House' 3D-Printed Models: An Extended Cohort Study with Volumetric Analysis.Journal of clinical medicine · 2026
- Technical Note - A patient-specific implant for orbital wall reconstruction with infraorbital rim extension: Accuracy and proof-of-principle evaluation of an "one-fit-only" design.Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2026
- Evaluation of the Accuracy of Zygomatic Complex Fracture Reduction and Orbital Volume Restoration Using A Full Digital Workflow Versus Conventional Protocol: A Randomized Clinical Trial.The Journal of craniofacial surgery · 2026
- MedReShaper: mesh-based AI for 3D anatomical shape completion in orbital fracture reconstruction with controlled technical validation.Medical image analysis · 2026
- Patient-specific implants are accurate and cost-effective for blow-out fracture reconstruction: a retrospective case-control study.Journal of plastic surgery and hand surgery · 2026
- PEEK patient-specific implants for orbital reconstruction: accuracy and clinical outcomes.The British journal of oral & maxillofacial surgery · 2026