Wearable echocardiography enables real-time perioperative monitoring in a pediatric liver transplant recipient with hepatopulmonary syndrome and pulmonary arteriovenous malformations: a case report.
Mao Ye, Pengjie Zhang, Chunling Jiang, Bin Zhou, Xinmei Yang, Haibo Song, Weiyi Zhang
Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, 610041, China. · Sichuan Wismed Medical Technology Co. Ltd, Chengdu, China.
Key points
From the paper's conclusion- This is the first detailed report demonstrating the utility of wearable echocardiography for continuous, real-time cardiac monitoring in a pediatric liver transplant recipient with severe HPS and PAVMs. This technology may facilitate individualized fluid management and enable early warning of catastrophic complications in pediatric liver transplantation when standard echocardiographic modalities are contraindicated or insufficient.
Abstract
BACKGROUND: Hepatopulmonary syndrome (HPS) with pulmonary arteriovenous malformations (PAVMs) creates high risks of hemodynamic instability and gas embolism during pediatric liver transplantation. Transesophageal echocardiography is relatively contraindicated due to esophageal varices, while intermittent transthoracic echocardiography lacks the temporal resolution to capture transient events. This is the first report of continuous wearable echocardiography for real-time perioperative monitoring in a pediatric liver transplant recipient with HPS and PAVMs. CASE PRESENTATION: A 3-year-old girl with biliary atresia and decompensated cirrhosis underwent deceased donor liver transplantation. Preoperative evaluation confirmed severe HPS with PAVMs. During surgery, fluid management was guided by continuous monitoring using wearable echocardiography to maintain hemodynamic stability. In particular, within 10 s after graft reperfusion, wearable echocardiography revealed numerous bright echogenic foci in all visualized cardiac chambers. This real-time finding provided immediate visual confirmation of gas embolism, which was associated with targeted multidisciplinary intervention. The surgery was successfully completed, and the patient was discharged on postoperative day 24. CONCLUSIONS: This is the first detailed report demonstrating the utility of wearable echocardiography for continuous, real-time cardiac monitoring in a pediatric liver transplant recipient with severe HPS and PAVMs. This technology may facilitate individualized fluid management and enable early warning of catastrophic complications in pediatric liver transplantation when standard echocardiographic modalities are contraindicated or insufficient.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prolonged VV-ECMO as a Bridge to Recovery From Persistent Hepatopulmonary Syndrome After Liver Transplantation: A Case Report.Clinical case reports · 2026
- Targeted neonatal echocardiography-guided characterisation and determination of thresholds for definitive intervention for congenital hepatic vascular malformationCardiology in the Young · 2026
- Multimodal Wearable Sensor System for Continuous Peripheral Circulation Monitoring in Postoperative Flap Care.Advanced healthcare materials · 2026
- Intraoperative transesophageal echocardiography in liver transplantation: A systematic review of clinical utility in managing hemodynamic challenges and complications.Tzu chi medical journal · 2026
- Transcatheter closure of patent ductus venosus in an adolescent using a KONAR-Multifunctional Occluder device.Annals of pediatric cardiology · 2026
- Effective perioperative management of Abernethy Malformation for complex congenital cardiac surgery utilizing zero-balance ultrafiltrationThe Journal of ExtraCorporeal Technology · 2026