Achieving low intraocular pressure in normal-tension glaucoma with the Preserflo MicroShunt: comparison with primary open-angle glaucoma and the XEN-45 Gel Stent.
Emil Nasyrov, Lasse Wolfram, Felix F Reichel, Caroline J Wenzel, Bogomil Voykov
Centre for Ophthalmology, University Hospital Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany. emil.nasyrov@med.uni-tuebingen.de. · Centre for Ophthalmology, University Hospital Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
Key points
From the paper's conclusion- PMS implantation enabled a high rate of sustained low IOP control, with significantly higher success rates than in matched POAG patients and NTG XEN-45 patients, while requiring fewer postoperative interventions. These findings indicate that the PMS might achieve lower IOP thresholds in NTG than previously expected requiring evaluation in larger prospective studies.
Abstract
BACKGROUND: Achieving low intraocular pressure (IOP) while minimizing surgical risk remains a central challenge in the management of normal-tension glaucoma (NTG). This study aimed to evaluate the efficacy and safety of the Preserflo MicroShunt (PMS) in NTG compared with primary open-angle glaucoma (POAG) and the XEN-45 Gel Stent. METHODS: In this retrospective dual-comparison study, the primary outcomes were 2-year complete success (≥ 30% reduction in IOP from baseline and ≤ 12 mmHg without medication) and hazard ratios (HRs) for surgical failure. Kaplan-Meier analyses and univariate Cox models were used to compare NTG PMS and POAG PMS patients (1:1 matched cohort; PMS analysis) and exploratory multivariable models for consecutive NTG PMS and NTG XEN-45 patients (NTG analysis). Secondary outcomes included bleb revision and complication rates. RESULTS: In the PMS analysis, 50 NTG patients were matched to 50 POAG patients. Two-year success rates were 69% and 45%, respectively (p = 0.0277). NTG diagnosis was associated with a lower risk of failure (HR 0.48, 95% CI 0.24-0.96) and fewer bleb revisions. In the NTG analysis, 45 PMS patients were compared with 23 XEN-45 patients. Two-year success rates were 71% and 17%, respectively (p < 0.0001). PMS implantation was associated with a lower risk of failure (HR 0.25, 95% CI 0.12-0.53) and fewer needling procedures. No sight-threatening complications occurred in any group. CONCLUSIONS: PMS implantation enabled a high rate of sustained low IOP control, with significantly higher success rates than in matched POAG patients and NTG XEN-45 patients, while requiring fewer postoperative interventions. These findings indicate that the PMS might achieve lower IOP thresholds in NTG than previously expected requiring evaluation in larger prospective studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of intraluminal stent placement on 18-month outcomes of Preserflo MicroShunt in Japanese patients with open-angle glaucomaJapanese Journal of Ophthalmology · 2026
- One-Year Outcomes of PreserFlo MicroShunt implantation Using Intraoperative Sub-Tenon Triamcinolone Acetonide.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Preserflo microshunt outcomes in pigmentary glaucoma: a propensity score-matched comparison with primary open-angle glaucoma.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
- Comparative outcomes of PreserFloTMMicroShunt in primary open-angle and pseudoexfoliative glaucoma: A matched analysis.PloS one · 2026
- PreserFlo MicroShunt Outcomes in Asia: Two-Year Results with Exploratory Comparisons of Standalone and Combined Surgery from a Regional Tertiary Centre.Journal of clinical medicine · 2026
- Comparison of Early Outcomes of PreserFlo MicroShunt, Ex-PRESS, and Trabeculectomy in Primary Open-angle Glaucoma.Journal of glaucoma · 2026