Prediction error in low power intraocular lens in highly myopic eyes.
Nicolas Mandrillon, Christophe Panthier, Damien Gatinel, Aude Couturier, Elise Philippakis
Université Paris Cité, Ophthalmology Department, AP-HP, Hôpital Lariboisière, Paris, France. · Ophthalmology Department, Hôpital Fondation Adolphe de Rothschild, Paris, France.
Key points
From the paper's conclusion- SRK/T exhibited a frequent hyperopic shift in highly myopic eyes, driven primarily by the poor performance with plano and negative power meniscus IOLs. This highlights the clinical need for optimizing A-constants for SRK-T formula at low powers and mandates the routine use of modern formulas like Barrett II or Pearl-DGS in this specific population.
Abstract
PURPOSE: To assess refractive prediction error (RPE) after cataract surgery in highly myopic eyes, focusing on the accuracy of intraocular lens (IOL) power calculations using the SRK/T formula without axial length adjustment. SETTING: Tertiary ophthalmology department at Lariboisière Hospital, Paris, France. Retrospective observational study. METHODS: We reviewed the records of eyes with axial length ≥ 26.5 mm that underwent cataract surgery between January 2019 and December 2021. RPE was defined as the difference between achieved and predicted spherical equivalent using SRK/T. We analyzed the absolute prediction error, proportion of eyes within ± 0.5D of target, and the direction of the error (hyperopic/myopic). Subgroup analyses were performed based on IOL power, especially plano and negative lenses, and the impact of implant-specific A-constant adjustments. Results were compared with predictions from the Barrett II and Pearl-DGS formulas. RESULTS: A total of 102 eyes from 71 patients were included. 61% achieved RPE within ± 0.5D. The mean absolute error was + 0.50 ± 0.49 D. Distribution of the signed prediction error showed a 60% hyperopic shift. The plano/negative IOL subgroup (n = 26) showed a significantly higher RPE (+ 0.93 ± 0.68 D, p < 0.001), with a hyperopic shift in 85% of cases. This was associated with IOLs lacking optimized A-constants with SRK-T formula at low/negative power. Barrett II (0.56 ± 0.36 D) and Pearl-DGS (0.57 ± 0.45 D) significantly reduced RPE and hyperopic shift in this subgroup (p < 0.05). CONCLUSIONS: SRK/T exhibited a frequent hyperopic shift in highly myopic eyes, driven primarily by the poor performance with plano and negative power meniscus IOLs. This highlights the clinical need for optimizing A-constants for SRK-T formula at low powers and mandates the routine use of modern formulas like Barrett II or Pearl-DGS in this specific population.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association Between Lens Thickness and SRK/T Refractive Prediction Error After Cataract Surgery: A Single-Center Retrospective Cohort Study.Journal of ophthalmology · 2026
- Evaluation of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes: A Systematic Review and Network Meta-Analysis.Journal of clinical medicine · 2026
- Efficacy of Total Keratometric Power and Total Corneal Power on the Accuracy of 8 Modern Intraocular Lens Formulas in Highly Myopic Eyes.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Best formulas for highly myopic patients (axial length ≥26 mm) receiving cataract surgery.Current opinion in ophthalmology · 2026
- Fellow eye parameter substitution for IOL calculation in APAC.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
- Comparison of IOL Power Calculation Formulas After Sutureless Intrascleral One-Piece IOL Fixation: A Post-hoc Analysis.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026