Evaluation of Bruch's membrane opening minimum rim width and retinal nerve fiber layer in patients with glaucoma and comparison with normal population.
Mustafa Davas, Halit Oguz
Department of Ophthalmology, Bartın State Hospital, Bartın, 74100, Turkey. mustafadavas.326@gmail.com. · Department of Ophthalmology, Istanbul Medipol University, Camlica Hospital Eye Clinic, Uskudar, Istanbul, Turkiye, 34696, Turkey.
Key points
From the paper's conclusion- BMO-MRW is a reliable and effective parameter for the early diagnosis of glaucoma, showing consistent global and sectoral diagnostic performance compared with APS-RNFL.
Abstract
PURPOSE: To assess and compare the diagnostic performance of Bruch's membrane opening-minimum rim width (BMO-MRW) and retinal nerve fiber layer (RNFL) thickness parameters in patients with early-stage glaucoma. MATERIAL AND METHOD: This observational cross-sectional study included 60 eyes with primary open-angle glaucoma, 44 eyes with ocular hypertension (OHT), and 41 healthy control eyes. One eye per participant was randomly selected. All subjects underwent comprehensive ophthalmologic evaluation, including Goldmann applanation tonometry, gonioscopy, standard automated perimetry, spectral-domain optical coherence tomography, and dilated fundus examination. Global and sectoral RNFL thickness measurements, including standard and Anatomical Positioning System-based RNFL (APS-RNFL), as well as BMO-MRW parameters, were obtained using the Glaucoma Module Premium Edition (GMPE). Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC) globally and across six Garway-Heath sectors. RESULTS: For discrimination between glaucoma and healthy controls, global BMO-MRW demonstrated satisfactory diagnostic performance comparable to APS-RNFL, with AUROC values of 0.783 (95% CI: 0.690-0.859) and 0.827 (95% CI: 0.739-0.895), respectively. The highest AUROC for APS-RNFL was observed in the inferotemporal sector (0.810), while BMO-MRW showed its highest performance in the superotemporal sector (0.800), with no significant difference between the two parameters. BMO-MRW exhibited consistently good diagnostic accuracy across all sectors, whereas APS-RNFL demonstrated reduced performance in the superonasal, nasal, and inferonasal sectors (AUROC <0.7). In differentiating OHT from healthy controls, global BMO-MRW outperformed APS-RNFL (AUROC: 0.625 vs. 0.504). CONCLUSIONS: BMO-MRW is a reliable and effective parameter for the early diagnosis of glaucoma, showing consistent global and sectoral diagnostic performance compared with APS-RNFL.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Baseline Macular OCT Thickness of Ocular Hypertensive Patients Improves Prediction of Glaucoma.American journal of ophthalmology · 2026
- High Myopia-Induced Optic Nerve Head Deformation and Glaucoma Progression: A Three-Year Follow-Up StudyInvestigative Ophthalmology & Visual Science · 2025
- Contrast-to-noise Ratios to Evaluate the Added Value of the Ganglion Cell Complex Thickness for the Detection of Progression in Glaucoma.Journal of glaucoma · 2026
- Macular Ganglion Cell-Inner Plexiform Layer (GCIPL) Thickness and Thinning Patterns for Differentiating Glaucomatous and Non-Glaucomatous Optic Neuropathy: A Prospective Comparative Study.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Comparison of Structure-Function Relationships between Tablet-Based Perimetry and Conventional Bowl Perimetry: a Cross-Sectional Study.Ophthalmology. Glaucoma · 2026
- Compatibility of 24-2C central extra test points with OCT and OCTA parameters in early-stage glaucoma.International journal of ophthalmology · 2026