BMC pregnancy and childbirth

Combined albumin-adjusted ischemia-modified albumin ratio and uterine artery Doppler for differentiating early-onset preeclampsia from gestational hypertension: a prospective exploratory pilot study.

Serkan Özbey, Handan Turhan Karakuş, Alper Gümüş, Pakizer Banu Kılıçoğlu Dane

Department of Obstetrics and Gynecology, SBÜ Başakşehir Çam and Sakura City Hospital, Istanbul, Turkey. serkanozbey1129@gmail.com. · Department of Obstetrics and Gynecology, SBÜ Başakşehir Çam and Sakura City Hospital, Istanbul, Turkey.

Observational

Key points

From the paper's conclusion
  • Combining IMAR with UtA-PI MoM may provide complementary information for distinguishing EO-PE from GHT at initial presentation. This exploratory model is not intended to replace established angiogenic biomarkers and requires validation in larger, multicenter studies before clinical application.

Abstract

BACKGROUND: Distinguishing early-onset preeclampsia (EO-PE) from gestational hypertension (GHT) at initial presentation remains challenging, particularly when classical diagnostic features are absent or evolving. We evaluated whether combining the albumin-adjusted ischemia-modified albumin ratio (IMAR) with uterine artery pulsatility index expressed as multiples of the median (UtA-PI MoM) provides complementary information in this setting. METHODS: In this prospective single-center exploratory study, 90 singleton pregnancies (30 EO-PE, 30 GHT, 30 controls) were included. IMAR and UtA-PI MoM were assessed individually and in combination using receiver operating characteristic analysis and logistic regression with bootstrap internal validation. RESULTS: IMAR and UtA-PI MoM were higher in EO-PE than in GHT (p = 0.003 and p < 0.001, respectively), whereas raw IMA did not distinguish the groups. IMAR demonstrated moderate discrimination (AUC 0.727, 95% CI 0.600-0.854), and UtA-PI MoM demonstrated higher performance (AUC 0.844, 95% CI 0.743-0.946). The combined model showed the highest apparent discrimination (AUC 0.898, 95% CI 0.818-0.977; optimism-corrected AUC 0.889), with 83.3% sensitivity and 86.7% specificity at the exploratory operating point. CONCLUSIONS: Combining IMAR with UtA-PI MoM may provide complementary information for distinguishing EO-PE from GHT at initial presentation. This exploratory model is not intended to replace established angiogenic biomarkers and requires validation in larger, multicenter studies before clinical application.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers