Evaluating Gates' GFR accuracy in renal tumor patients through integration of standalone CT-derived renal depth estimation via deep learning segmentation: a preliminary study.
Chunxing Wu, Guangfeng Chen, Qing Liao, Feng Zhang, Liangjun Xie, Yueming Zha
Department of Nuclear Medicine, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Tianhe District, Guangzhou City, Guangdong Province, China. wuchx25@mail.sysu.edu.cn. · Department of Nuclear Medicine, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Tianhe District, Guangzhou City, Guangdong Province, China.
Key points
From the paper's conclusion- In this preliminary cohort, Gates' GFR calculation incorporating standalone abdominal CT-derived RD estimation via deep learning-based segmentation was associated with a higher correlation with DPSM and descriptively smaller absolute differences from DPSM than conventional Gates GFR with Tonnesen-derived RD estimation in patients with renal tumor. By leveraging existing diagnostic CT imaging, this method provided an exploratory, patient-specific RD estimation strategy and GFR calculation without requiring an additional CT acquisition, but its reliability and clinical utility warrant further validation in a larger cohort.
Abstract
BACKGROUND: Gates' Glomerular Filtration Rate (GFR) measurement via SPECT dynamic renal scintigraphy is common in clinical practice. However, its accuracy is limited by the variability of renal depth (RD) estimated by the conventional height- and weight-based Tonnesen formula, particularly in patients with renal tumors. This study compared a novel standalone CT RD estimation via deep learning segmentation and GFR measurement method against the Tonnesen formula between renal tumor and non-tumor groups, using the double plasma sample method (DPSM) as the reference standard. METHODS: A retrospective analysis was conducted on 99 patients from January to December 2024, categorized into renal tumor group (n = 23) and non-tumor group (n = 76). All patients underwent 99mTc-DTPA SPECT/CT dynamic renal scintigraphy, standalone abdominal CT, serum creatinine (Scr) testing, and DPSM. Five GFR measurement methods were compared and analyzed : (1) Gates' method with deep learning-based standalone CT segmentation and RD estimation, (2) Gates' method using Tonnesen's RD via Siemens software, (3) Gates' method using Tonnesen's RD via MMIS software, (4) Scr-based estimation, and (5) DPSM serving as the reference standard. Welch's independent t-tests were conducted statistically to compare various GFRs between tumor and non-tumor groups. Pearson correlation coefficients were used to evaluate relationships among the various GFR methods. RESULTS: Standalone CT-derived RDs were greater than Tonnesen formula estimation. Particularly in the tumor group, CT-derived vs. Tonnesen RDs were 7.30 ± 1.51 cm vs. 5.97 ± 1.07 cm (left), and 7.15 ± 1.27 cm vs. 6.01 ± 1.08 cm (right). The mean total GFR measurements using the reference standard DPSM, CT-derived RD, Tonnesen's RD via Siemens and MMIS software, and Scr-based, were 87.91 ± 19.53, 94.61 ± 28.11, 77.29 ± 17.93, 79.28 ± 23.98, and 81.71 ± 23.31 mL/min for the tumor group, 77.56 ± 11.04, 81.30 ± 30.67, 68.07 ± 22.86, 68.22 ± 24.16, and 76.15 ± 30.65 mL/min for the non-tumor group. The CT-based measurements showed numerically higher correlation with DPSM (r = 0.915 for the tumor group; r = 0.825 for the non-tumor group), compared with Tonnesen-based measurements (r < 0.8 for both subgroups). In paired method-comparison analysis, the CT-based GFR calculation showed descriptively smaller absolute differences from DPSM (21.47 mL/min) than the Tonnesen-based GFR methods (Siemens: 32.57 mL/min, MMIS: 27.04 mL/min) in tumor group. CONCLUSIONS: In this preliminary cohort, Gates' GFR calculation incorporating standalone abdominal CT-derived RD estimation via deep learning-based segmentation was associated with a higher correlation with DPSM and descriptively smaller absolute differences from DPSM than conventional Gates GFR with Tonnesen-derived RD estimation in patients with renal tumor. By leveraging existing diagnostic CT imaging, this method provided an exploratory, patient-specific RD estimation strategy and GFR calculation without requiring an additional CT acquisition, but its reliability and clinical utility warrant further validation in a larger cohort.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Estimation of glomerular filtration rate by standard renal CT imaging.Insights into imaging · 2026
- The Relationship Between Estimated and Measured Glomerular Filtration Rate in Pediatric Hematopoietic Stem Cell Transplant Candidates.Pediatric transplantation · 2026
- Diagnostic accuracy of Chronic Kidney Disease Epidemiology Collaboration 2021 and Janowitz-estimated glomerular filtration rate for identifying renal dysfunction compared with 99mTc-DTPA in patients with locally advanced cervical cancer.International journal of gynecological cancer : official journal of the International Gynecological Cancer Society · 2026
- Refining absolute GFR estimation in children: development and validation of the GROW-GFR equation.Frontiers in pharmacology · 2026
- Precisely Staging Diabetic Nephropathy by a Gold-Based Artificial Filtration Biomarker through Computed Tomography and Blood Testing of the Glomerular Filtration RateACS Nano · 2026
- Development of a deep learning model for glomerulus detection and segmentation in kidney histopathology imagesmedRxiv · 2026