Transperineal strain elastography for evaluating periurethral biomechanics in women with stress urinary incontinence: a diagnostic accuracy study.
Amir Hossein Shahbazkhani, Fatemeh Shakki Katouli, Sarah Torabi, Fahimeh Zeinalkhani, Faezeh Khorasanizadeh, Ala Torabi, Rana Karimi, Hedayat Abbastabar
Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Medical Imaging Center, Tehran University of Medical Sciences, Tehran, Iran. · Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Medical Imaging Center, Tehran University of Medical Sciences, Tehran, Iran. Fatemeh.shakki@gmail.com.
Key points
From the paper's conclusion- Transperineal SE detected group-level differences in relative periurethral deformation during Valsalva, but strain-ratio measures showed poor standalone diagnostic performance. In this sample, SE did not demonstrate improved discrimination beyond conventional kinematic parameters; however, the modest sample size and lack of internal validation limit the certainty and generalizability of this finding. BND and RVA remained substantially more accurate. Accordingly, SE should currently be regarded as an exploratory biomechanical research measure rather than a diagnostic test for SUI, and its potential complementary role requires further validation.
Abstract
BACKGROUND: Stress urinary incontinence (SUI) commonly reflects loss of urethral support and altered periurethral biomechanics. Strain elastography (SE) can quantify tissue deformation; however, its clinical diagnostic value for SUI is uncertain. OBJECTIVE: To evaluate periurethral strain elastography in women with and without SUI and to compare its diagnostic performance with established kinematic ultrasound parameters. METHODS: In a prospective case-control study, 43 premenopausal women (23 SUI, 20 controls) underwent standardized transperineal B-mode ultrasound and strain elastography. Four periurethral ROIs-posterior-mid (A1), anterior-mid (A2; prespecified primary outcome), posterior-upper (A3), and anterior-upper (A4)-were sampled at rest and during Valsalva. Kinematic measures (bladder-neck descent [BND], retrovesical angle [RVA]) were recorded. Analyses used parametric or nonparametric tests as appropriate, Cohen's d effect sizes, bootstrap 95% CIs (2,000 replicates), ROC curves, and exploratory logistic regression models. RESULTS: Groups were similar in age and BMI. At rest, strain ratios (SRs) did not differ. During Valsalva maneuver, however, controls demonstrated significantly higher strain ratios than SUI cases in all four regions, including posterior-mid (A1; p = 0.006), anterior-mid (A2; p = 0.003), posterior-upper (A3; p = 0.037), and anterior-upper (A4; p = 0.004), demonstrating consistently higher relative periurethral strain-ratio values in controls during Valsalva. Despite statistically significant mean differences, SR variables showed poor raw discriminatory performance on ROC analysis (AUC range 0.248-0.336), reflecting an unexpected direction of discrimination (controls having higher, "stiffer," SR values than cases). In contrast, kinematic parameters demonstrated excellent diagnostic accuracy: RVA during Valsalva yielded an AUC of 0.953 (95% CI, 0.878-1.000), and BND yielded an AUC of 0.896 (95% CI, 0.785-0.993). In this sample, multivariable regression did not demonstrate a statistically significant incremental diagnostic benefit from SE beyond kinematic measures; however, the modest sample size and lack of internal validation limit the certainty of this finding. CONCLUSIONS: Transperineal SE detected group-level differences in relative periurethral deformation during Valsalva, but strain-ratio measures showed poor standalone diagnostic performance. In this sample, SE did not demonstrate improved discrimination beyond conventional kinematic parameters; however, the modest sample size and lack of internal validation limit the certainty and generalizability of this finding. BND and RVA remained substantially more accurate. Accordingly, SE should currently be regarded as an exploratory biomechanical research measure rather than a diagnostic test for SUI, and its potential complementary role requires further validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Agreement between pelvic floor muscle assessment methods in women with stress urinary incontinence: a cross-sectional studyScientific Reports · 2026
- Transperineal Ultrasound Comparison of Longitudinal Sling Position and Dynamic Sling Configuration After Altis and MiniStop Single-Incision Mini-Slings for Stress Urinary Incontinence.Biomedicines · 2026
- Intraoperative Ultrasound Guided Sling Adjustment During Transobturator Sling Placement: A Preliminary Pilot Report of the Technical Protocol and Feasibility.International journal of urology : official journal of the Japanese Urological Association · 2026
- Post-Surgical Evaluation in Stress Urinary Incontinence by Transperineal Ultrasound and Quality of Life Questionnaire-A Retrospective Study.Diagnostics (Basel, Switzerland) · 2026
- Transrectal Biplane Ultrasound Combined with Cotton Swab Marking of the External Urethral Orifice for Evaluating the Postoperative Position of Transobturator Mid-Urethral Sling: A Study on Standardized Ultrasound Measurement and Inter-Observer Reliability.Diagnostics (Basel, Switzerland) · 2026
- Assessment of Sling Characteristics After Transobturator Tape Placement Using Transperineal Ultrasonography: Relationship with Continence and Dyspareunia-A Cross-Sectional Study.Journal of clinical medicine · 2026