Updating the COVID-GRAM linear predictor for in-hospital mortality: calibration and the incremental prognostic value of room-air oxygen saturation at presentation
Hasan Burak Toprak, Gökhan Ersunan
Key points
From the paper's conclusion- We compared the frozen predictor (M1), intercept-only recalibration (M2), intercept-and-slope recalibration (M3), and M3 plus a three-knot SpO₂ spline (M4), with SpO₂ alone (M0).
Abstract
Background COVID-GRAM predicts composite critical illness. We examined transport of its published linear predictor to in-hospital mortality, mortality-specific recalibration, and the incremental prognostic value of room-air peripheral oxygen saturation (SpO₂) at presentation. Methods This retrospective secondary analysis used a previously published single-centre cohort from Türkiye (August 2020–January 2021): 294 unique adults and 77 deaths (26.2%). We compared the frozen predictor (M1), intercept-only recalibration (M2), intercept-and-slope recalibration (M3), and M3 plus a three-knot SpO₂ spline (M4), with SpO₂ alone (M0). Performance assessment included discrimination, calibration, Brier score, and exploratory decision curves. Bootstrap internal validation repeated model fitting and empirical knot estimation; two-stage bootstrap procedures quantified uncertainty. Results M1 had an AUC of 0.883 (95% confidence interval [CI] 0.839–0.927), calibration-in-the-large of 0.076 (− 0.241 to 0.393), and calibration slope of 1.250 (0.946–1.554). Nested comparisons provided insufficient evidence for intercept ( p = 0.639) or slope updating ( p = 0.086). M4 had an apparent AUC of 0.963 and an optimism-corrected AUC of 0.958 (95% bootstrap CI 0.940–0.980). Its corrected AUC exceeded M3 by 0.075 (0.044–0.121); the SpO₂ likelihood-ratio test yielded χ²=82.4 (2 df; p < 0.001). M4’s corrected Brier score was 0.072 (0.049–0.089), and its corrected calibration slope was 0.915. M0’s apparent AUC was 0.908; the COVID-GRAM linear predictor added information beyond M0 (χ²=62.9, 1 df; p < 0.001). Decision-curve findings remained exploratory. Conclusions Within this historical cohort, room-air SpO₂ provided additional prognostic information beyond the COVID-GRAM predictor after mortality-specific recalibration. The additional complexity and data requirements of M4 have not been shown to provide clinically meaningful benefit over SpO₂ alone. The small sample, retrospective ascertainment, and shared model-fitting and evaluation cohort limit interpretation. These internally assessed results do not establish transportable mortality risks or clinical usefulness; independent contemporary external validation is required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transportability, calibration, and alert burden of an hourly model for documented continuous vasopressor initiation: a retrospective three-database studyFrontiers in Medicine · 2026
- Competing Risk Prediction of COVID-19 Hospital Mortality with Model Diagnostics and Exploratory Evaluation in Mexico.Diagnostics (Basel, Switzerland) · 2026
- Predicting Sepsis in ICU Patients Using GRU-D and LightGBM for Clinical Decision SupportInternational Journal on Smart Sensing and Intelligent Systems · 2026
- Subgroup deployment-readiness audit of calibration and clinical utility in perioperative infection prediction.Journal of the American Medical Informatics Association : JAMIA · 2026
- Augmenting the Simplified Acute Physiology Score II for intensive care unit mortality prediction and benchmarking: a French nationwide studyCritical Care · 2026
- Machine Learning Models for Predicting Unplanned Readmission and Mortality in the ICU: A Systematic Review and Meta-AnalysisBig Data and Cognitive Computing · 2026