From the paper's conclusion- The results of this study indicate that the GBP5 CLIA assay is a potential test for aTB diagnosis and LTBI screening.
Abstract
BACKGROUND: A major challenge in tuberculosis control is distinguishing latent infection from active disease, creating an urgent need for more precise and sensitive diagnostics. Recent literature has suggested that guanylate-binding protein 5 (GBP5) may serve as biomarkers of tuberculosis (TB) diagnosis. The aim of this study was to evaluate a GBP5 assay in TB antigen-stimulated blood and to compare its analytical and diagnostic performance with traditional interferon-gamma release assay (IGRA). METHODS: The analytical performance of the newly developed GBP5 chemiluminescence assay (CLIA) was evaluated, including the limit of detection, precision, and interference studies. A total of 571 participants, including 183 TB patients, 69 latent tuberculosis infection (LTBI) individuals and 319 control participants, were enrolled in the study. The whole blood was collected and detected using IGRA and GBP5-CLIA. RESULTS: A chemiluminescence-based GBP5 assay was demonstrated, with a measurement range of 97.66-50,000 pg/mL, a limit of detection of 11.37 pg/mL. The intra-assay precision coefficient of variation was less than 5%, and interference rates remained within ± 10% in the presence of haemoglobin (≤ 5000 mg/dL) and bilirubin (≤ 300 mg/dL), indicating high sensitivity, precision, and good anti-interference capability. In the clinical cohort, GBP5 expression in stimulated whole blood was significantly greater in active tuberculosis (aTB) patients than in non-TB individuals (p < 0.001). Receiving operating characteristic analysis revealed that GBP5 achieved an area under the curve (AUC) of 0.8821 (95% CI, 0.8511 to 0.9132) for diagnosing aTB, with a sensitivity of 85.8% and specificity of 83.4%, which is comparable to that of IGRA (AUC = 0.9085). Furthermore, GBP5 demonstrated a moderate ability to discriminate aTB from latent TB infection (LTBI) (AUC = 0.667, sensitivity 63.39%, specificity 67.16%). CONCLUSIONS: The results of this study indicate that the GBP5 CLIA assay is a potential test for aTB diagnosis and LTBI screening. CLINICAL TRIAL REGISTRATION: Not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and validation of a blood-based diagnostic model for pulmonary tuberculosis combining GBP5 expression and routine laboratory indicators.Medicine · 2026
- Diagnostic performance of an automated qRT-PCR assay using a peripheral blood host 5-mRNA signature for active tuberculosis: a single-center prospective cohort study and external validation in public databases.International journal of infectious diseases : IJID : official publication of the International Society for Infectious Diseases · 2026
- From host response to genomic targets: electrochemical biosensing of tuberculosis biomarkers.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- Novel RT‒qPCR-based blood signatures for the diagnosis of pulmonary tuberculosis.Scientific reports · 2026
- BATF2 Expression Versus a Six-Gene Interferon-Associated Blood Signature for Distinguishing Active Pulmonary Tuberculosis from Latent Infection: A Two-Cohort Transcriptomic Analysis.Medical sciences (Basel, Switzerland) · 2026
- Novel blood biomarkers distinguish active pulmonary tuberculosis from non-pulmonary tuberculosis: a prospective, large scale, clinical trial in Eastern China.Infection · 2026