Concurrent carotid structural and functional ultrasound findings in adults with high-normal blood pressure: a retrospective cross-sectional study
Qiwu Xu, Rongzhen Xu, Fan Bu, Yawen Wang, Xinyan Zhao, Yixuan Lin, Ruxin Ma, Yingzhen Xie
Dongzhimen Hospital Affiliated to Beijing University of Chinese Medicine
Key points
From the paper's conclusion- We compared concurrent quantitative arterial stiffness (QAS)-derived functional measures and quantitative intima–media thickness (QIMT) in adults with high-normal and ideal blood pressure.
Abstract
We compared concurrent quantitative arterial stiffness (QAS)-derived functional measures and quantitative intima–media thickness (QIMT) in adults with high-normal and ideal blood pressure. This retrospective cross-sectional study included adults assessed at Dongzhimen Hospital, Beijing, between November 2021 and December 2022. Four blood pressure groups were defined. Primary outcomes were maximum QIMT and mean carotid pulse wave velocity (PWV); distensibility coefficient (DC) and compliance coefficient (CC) were key secondary functional outcomes. Models adjusted for age, sex, and body mass index. Sensitivity analyses restricted the comparison to the ideal and high-normal groups and used E-values to quantify robustness to unmeasured confounding. Among 312 participants, 114 had ideal and 91 had high-normal blood pressure. The adjusted between-group difference in maximum QIMT was not statistically significant (standardized difference, − 0.04; 95% confidence interval [CI], − 0.25 to 0.17; false-discovery-rate-adjusted P = 0.761). High-normal blood pressure was associated with higher PWV (0.38; 95% CI, 0.21 to 0.56), lower DC (− 0.45; 95% CI, − 0.63 to − 0.27), and lower CC (− 0.42; 95% CI, − 0.67 to − 0.17); all remained significant after multiple-testing correction and QIMT adjustment. Restricted two-group analyses were consistent. Approximate E-values for the functional point estimates ranged from 2.61 to 3.35 and those for the confidence-interval limits ranged from 1.72 to 2.38. On the approximate risk-ratio scale, explaining the functional point estimates would require an unmeasured confounder to be associated with both blood pressure status and the functional outcome by risk ratios of at least 2.61 each, conditional on the measured covariates. High-normal blood pressure was associated cross-sectionally with QAS-derived functional differences, whereas no statistically significant adjusted difference in maximum QIMT was detected. These findings do not establish the absence of structural change, temporal precedence, or causality. not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical and Cardiometabolic Characteristics Associated with Elevated Office Central Systolic Blood Pressure in Individuals with Normal Brachial Systolic Blood PressureArtery Research · 2026
- Endothelial Function and Pulsatile Load in Relation to Cognitive Screening Performance and Albuminuria in Treated Hypertension: A Cross-Sectional StudyJournal of Clinical Medicine · 2026
- Office blood pressure measurement versus ambulatory blood pressure monitoring for detecting undiagnosed hypertension in an apparently healthy Mexican adult cohort: complementary central hemodynamic and arterial stiffness assessment.Frontiers in cardiovascular medicine · 2026
- Cigarette smoking exacerbates aortic elastic properties and increase carotid thickness in hypertensive males with higher non-HDL-CEuropean Heart Journal · 2026
- Average Real Variability Is an Independent Predictor of Increased Arterial Stiffness Assessed by Pulse Wave Velocity.Journal of clinical hypertension (Greenwich, Conn.) · 2026
- Association of Non-HDL-C/HDL-C Ratio (NHHR) with Early Vascular Aging in a Hypertension Referral Cohort: Development of a Clinical Prediction ModelJournal of Clinical Medicine · 2026