Artificial intelligence-enabled non-invasive quantification of left ventricular end-systolic pressure: an in silico analysis.
Edouard Long, Roberta Dunn, Vitaliy Androshchuk
Faculty of Life Sciences and Medicine, King's College London, London, UK. edouard.long@kcl.ac.uk. · Faculty of Life Sciences and Medicine, King's College London, London, UK.
Key points
From the paper's conclusion- In this hypothesis generating study, a novel non-invasive, AI-enabled approach to LVESP quantification incorporating age, PWV and other key hemodynamic parameters alongside brachial BPs yielded smaller average error across the lifespan than commonly used brachial BP-only equations. These results warrant validation in vivo to ascertain real-world predictive performance.
Abstract
BACKGROUND: Invasive pressure-volume loop (PVL) analysis is the gold standard method to quantify myocardial physiology. To enhance broader clinical applicability, non-invasive approaches to derive left ventricular (LV) PVLs have gained prominence, typically estimating LV end-systolic pressure (ESP) from brachial blood pressure (BP) alone. However, this approach does not account for factors that may modulate the pressure waveform as it propagates from the LV to the brachial artery, notably arterial stiffness. We trained an artificial-intelligence (AI) model to predict invasive LVESP from a set of non-invasive hemodynamic parameters and compared its performance with commonly used equations for estimating LVESP using solely brachial BPs. METHODS: An in silico cohort of healthy adults (N = 3,837, age: 48.6 ± 17.0y), previously shown to have good agreement for aortic and brachial BP with in vivo data, was split into training and validation cohorts using an internal hold-out validation approach. Clinically relevant parameters were selected as inputs to a random forest machine learning model. RESULTS: The best performing model included systolic and diastolic brachial BP, heart rate, age, and carotid-femoral pulse wave velocity (PWV), and reliably predicted LVESP (root mean square error: 0.99 mmHg). AI-derived LVESP correlated more strongly with simulated invasive LVESP (r = 0.994) than commonly used equations (r = 0.909-0.908). Bland-Altman analysis demonstrated significant bias in brachial BP-only equations (mean bias: -4.01, limits of agreement [LoA] [± 1.96 standard deviations]: -11.1 to 3.06 mmHg), with the direction of bias varying across different ages. AI-derived LVESP displayed smaller bias (mean bias: 0.002, LoA: -1.94 to 1.94 mmHg) and had negligible age-related bias across the lifespan. CONCLUSIONS: In this hypothesis generating study, a novel non-invasive, AI-enabled approach to LVESP quantification incorporating age, PWV and other key hemodynamic parameters alongside brachial BPs yielded smaller average error across the lifespan than commonly used brachial BP-only equations. These results warrant validation in vivo to ascertain real-world predictive performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence‐Enabled ECG for Elevated E/e' on Echocardiography: Hemodynamic Relevance and Prognostic ValueJournal of the American Heart Association · 2026
- Vascular stiffness–integrated ai model improves discrimination of poor responders to azilsartan–indapamide therapyEuropean Heart Journal · 2026
- Artificial intelligence-enabled electrocardiography for estimating left ventricular filling pressureEuropean Heart Journal · 2026
- Evolutionary Optimization of Extended Kalman Filter Hyperparameters for Adaptive Data-Driven ABP Prediction Framework Inspired by Cardiovascular Digital-Twin PrinciplesAlgorithms · 2026
- Association of ambulatory waveform-derived pulse wave velocity with blood pressure response to exercise: role of fitness correction.Journal of hypertension · 2026
- Prediction of Left Ventricular Systolic Dysfunction Using an Artificial Intelligence-Based Electrocardiogram Analysis Model in Patients Presenting to the Emergency Department.Diagnostics (Basel, Switzerland) · 2026