Key points
From the paper's conclusion- This study developed and validated a multimodal data-fusion model using VitalDB for 5-minute-ahead BIS prediction during the maintenance phase of intravenous anesthesia and evaluated its ability to provide early warning of BIS < 40.
Abstract
Background Bispectral index (BIS) monitoring primarily assesses the current depth of anesthesia and does not indicate future trends. Predicting future low BIS may give anesthesiologists time to assess potentially excessive depth of anesthesia in advance and reduce unnecessary exposure to deep anesthesia. This study developed and validated a multimodal data-fusion model using VitalDB for 5-minute-ahead BIS prediction during the maintenance phase of intravenous anesthesia and evaluated its ability to provide early warning of BIS < 40. Methods We selected 2,407 surgical cases from VitalDB and integrated BIS monitoring, vital signs, ventilation, and intravenous anesthetic medication data from the preceding 120 s during the maintenance phase of intravenous anesthesia with baseline clinical information to predict BIS at 300 s ahead. One window was generated every 120 s, and patients were assigned to the training and test sets at an approximately 75:25 ratio. A multimodal data-fusion model was developed using histogram-based gradient boosting (HGB) regression. The primary evaluation metric was mean absolute error (MAE). Observed 5-minute-ahead BIS < 40 was defined as the positive outcome for calculating the area under the receiver operating characteristic curve (AUROC). Predicted BIS < 40 was used as the early-warning rule to calculate sensitivity, specificity, positive predictive value, and negative predictive value. Patient-level paired bootstrap resampling was used to estimate 95% confidence intervals, and SHapley Additive exPlanations (SHAP) analysis was used to assess feature contributions. Results The MAE was 4.61 for the multimodal data-fusion model and 4.79 for BIS monitoring-only HGB, a relative reduction of 3.9%; the paired reduction was 0.19 (95% confidence interval: 0.16–0.22). With predicted BIS < 40 as the early-warning rule, the multimodal data-fusion model achieved an AUROC of 0.841, sensitivity of 67.8%, specificity of 83.4%, positive predictive value of 73.5%, and negative predictive value of 79.2%. Conclusions In test data from the maintenance phase of intravenous anesthesia, the multimodal data-fusion model improved 5-minute-ahead BIS prediction and discrimination of BIS < 40 compared with the BIS monitoring-only HGB model. Its MAE and RMSE indicated better predictive performance than that reported in previous related studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Depth-of-Anesthesia Monitoring in Closed-Loop Anesthesia Delivery with Open BIS Validation and Neuromorphic FeasibilityApplied Sciences · 2026
- Individualized intraoperative BIS targeting based on preoperative BIS values in the awake state: a review and strategy prospect for preventing postoperative delirium in older patients.Minerva anestesiologica · 2026
- Artificial Intelligence-Driven Continuous Biosignal Analysis in Anesthesia and Critical Care: Detection, State Assessment, and Adverse-Event Prediction: A Critical Narrative Review.Bioengineering (Basel, Switzerland) · 2026
- Paradoxical Combinations of Bispectral Index and Burst Suppression RatioAnesthesia & Analgesia · 2025
- The dynamics of arterial pressure itself predict intraoperative hypotension beyond its current value: an interpretable additive model validated in 3,069 external patients under a selection-bias-resistant protocolmedRxiv · 2026
- DSPONVNet: a multimodal deep learning model integrating intraoperative monitoring and clinical features for predicting postoperative nausea and vomiting riskBMC Medical Research Methodology · 2026