Emergency airway management of a relapsing polychondritis patient with tracheal stent migration: a case report.
Zhongliang Sun, Lingxue Zhang, Runjuan He, Yu Zhang, Yang Yang, Zhuang Miao
Department of Anesthesiology, The First Affiliated Hospital of Dalian Medical University, Zhongshang Road No. 222, Dalian, Liaoning, China. sunzhongliang@firsthosp-dmu.com. · Department of Anesthesiology, The First Affiliated Hospital of Dalian Medical University, Zhongshang Road No. 222, Dalian, Liaoning, China.
Key points
From the paper's conclusion- Emergency airway management in patients with tracheal stents is technically challenging, particularly in the presence of stent migration. Bronchoscopic guidance is essential to ensure proper alignment of the endotracheal tube with the stent lumen. Clinicians should anticipate altered airway anatomy and be prepared for complex airway interventions.
Abstract
BACKGROUND: Relapsing polychondritis (RP) is a rare autoimmune disorder characterized by recurrent inflammation of cartilaginous structures, frequently involving the tracheobronchial tree. Progressive airway involvement may result in tracheal stenosis and tracheobronchomalacia, often necessitating airway stent placement. Airway management in these patients is particularly challenging, especially in the presence of stent-related complications such as migration. CASE PRESENTATION: A 71-year-old man with RP and a history of tracheobronchial stent placement presented with respiratory distress following a traumatic fall. Emergency tracheal intubation was indicated due to progressive hypoxemia. Computed tomography (CT) revealed cephalad migration of the tracheal stent, resulting in misalignment between the stent lumen and the native airway. Rapid sequence induction was performed under video laryngoscopy. During intubation, significant gastroesophageal regurgitation occurred. A 7.0-mm endotracheal tube was initially positioned with the cuff at the level of the vocal cords to reduce the risk of aspiration. After thorough suctioning of gastric contents, the tube was advanced into the stent lumen under flexible bronchoscopic guidance. Bronchoscopy revealed airway collapse consistent with tracheobronchomalacia and impaired ventilation of the right lung due to stent malposition. Attempts to reposition the stent were unsuccessful. The patient subsequently developed severe pulmonary infection and acute respiratory distress syndrome (ARDS) and died two weeks later. CONCLUSIONS: Emergency airway management in patients with tracheal stents is technically challenging, particularly in the presence of stent migration. Bronchoscopic guidance is essential to ensure proper alignment of the endotracheal tube with the stent lumen. Clinicians should anticipate altered airway anatomy and be prepared for complex airway interventions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hybrid Spinal-General Anesthesia With a Supraglottic Airway in Severe Rheumatoid Arthritis: A Case Report.Cureus · 2026
- Previously Unrecognized Tracheobronchopathia Osteochondroplastica Diagnosed Following Unexpected Difficult Tracheal Intubation During Robotic Surgery: A Case Report and Literature Overview.Clinical case reports · 2026
- Airway recanalization followed by montgomery T-tube placement for severe subglottic stenosis in an adolescent: a case report.Frontiers in medicine · 2026
- When Postextubation Stridor Is Not Edema: Bilateral Lateral Subglottic Mucosal Tears.Cureus · 2026
- Failed Awake Flexible Intubation Followed by Early Surgical Tracheostomy in Advanced Laryngeal Cancer: A Case Report.Case reports in anesthesiology · 2026
- Tracheo-bronchial stenosis and chronic inflammatory diseases: challenges and management strategiesFrontiers in Medicine · 2026