ERMA: a harmonizing epicPCR data analysis tool.
Adrian Dörr, Svjetlana Dekić Rozman, Lina Viktoria Duncker, Jan Kehrmann, Jan Buer, Marko Virta, Folker Meyer, Ivana Kraiselburd
Data Science Research Group, Institute for Artificial Intelligence in Medicine (IKIM), University Hospital of Essen, University of Duisburg-Essen, Essen, Germany. · Institute of Microbiology, University of Helsinki, Helsinki, Finland.
Key points
From the paper's conclusion- By providing a transparent, modular, and reproducible workflow, ERMA contributes toward harmonized epicPCR data analysis and establishes a foundation for future methodological standardization and benchmarking efforts as reference datasets improve.
Abstract
BACKGROUND: EpicPCR links functional genes to taxonomic markers at the single-cell level and has become an important method in microbial ecology and antimicrobial resistance research. However, the lack of missing standardized data analysis workflows limits reproducibility and comparability across studies. Existing analyses are often based on custom, unpublished scripts, complicating cross-study benchmarking and reuse. RESULTS: We present ERMA, an open-source, Snakemake-based pipeline that enables an automated, standardized, reproducible, and scalable epicPCR data analysis with minimal user input. ERMA supports both Illumina and ONT sequencing data and integrates quality control, database preparation, dual similarity searches against taxonomic and functional reference databases, results integration, filtering, and visualization. The pipeline is adaptable to a broad range of research questions beyond AMR due to modular database preparation and integration of specific UniRef queries. We evaluated ERMA using five publicly available epicPCR datasets covering diverse sample sources and sequencing depths. Across these datasets, ERMA achieved mean concordance rates of approximately 70-83% with the taxonomic results reported in the respective publications. In addition, validation using a defined five-member mock community spiked into clinical wastewater demonstrated full recovery of mock genera, with 85% of ERMA-detected genera also detected by independent 16S rDNA gene analysis of the same wastewater sample. Attrition analysis showed inconsistent filtering patterns across studies, reflecting dataset-specific quality differences. CONCLUSION: While large-scale reference datasets for epicPCR remain limited, validation using both publicly available studies and a defined mock community shows strong, interpretable performance across heterogeneous datasets. By providing a transparent, modular, and reproducible workflow, ERMA contributes toward harmonized epicPCR data analysis and establishes a foundation for future methodological standardization and benchmarking efforts as reference datasets improve.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 16S-Pipeline: A comprehensive web-based platform for end-to-end 16S rRNA amplicon sequencing analysisThe Journal of Microbiology · 2026
- PUDU (pipeline for universal diversity unveiling): an accessible end-to-end workflow for taxonomic profiling and ecological visualization of environmental microbiomes across amplicon, shotgun, and long-read sequencingFrontiers in Bioinformatics · 2026
- MGnify analyses in 2027: enhancing the depth and breadth of analyses across metabarcoding, unassembled metagenomes, and assembled datasets.Nucleic acids research · 2026
- Database-Pipeline Interactions Shape Taxonomic Inference in 16S rRNA Bacterial Community ProfilingISME Communications · 2026
- SeCAT (Sequence Consensus Amplicon Trimming): a simulation-informed Nextflow pipeline for cross-study harmonisation of 16S rRNA metabarcoding datasetsbioRxiv · 2026
- An in-depth, updated benchmark for 16S amplicon sequencingbioRxiv · 2026