Treatment of a Distal Pole Patellar Nonunion With Open Fragment Excision and Patellar Tendon Repair With a Double Loaded Knotless All-Suture Suture Anchor.
Alexander J Egol, Kaisen Yao, Dylan T Lowe, Andrew S Bi
NYU Langone Orthopedic Hospital, New York, New York, USA.
Key points
From the paper's conclusion- Based on existing outcomes of operative management for recalcitrant patellar tendinopathy, the patient is expected to return to her preinjury level of activity with excellent functional outcomes.
Abstract
BACKGROUND: There is limited literature specifically addressing the management of distal pole patellar nonunion, as most existing evidence focuses on cases of recalcitrant patellar tendinopathy. INDICATIONS: The patient described in the video had a distal pole patellar nonunion and failed nonoperative management due to persistent pain and functional limitations. There are a variety of described techniques to manage this condition. The authors chose to perform open fragment excision with patellar tendon repair using a knotless double-loaded all-suture suture anchor to eliminate knot stack interference. TECHNIQUE DESCRIPTION: The patient is positioned supine on a radiolucent table with the knee over a radiolucent triangle. A 4 cm incision is made over the distal pole nonunion site, and dissection is carried down to the paratenon. Small medial and lateral flaps are created to allow a mobile window. The nonunion site is identified, the patellar tendon is split, and the fragment is excised using sharp dissection. The distal pole of the patella is cleared of soft tissue to expose bleeding bone for healing. A drill and guide for a double-loaded knotless all-suture anchor are used to drill into the distal pole, parallel to the dorsal cortex. A knee-specific guide provides added stability. After seating the anchor, the first repair suture is placed with a running nonlocking whip stitch along the patellar tendon split. The second suture is passed in a crossing fashion, creating a watertight construct. Both sutures are brought proximally, loaded through the anchor system, and tensioned to achieve a knotless repair. Fluoroscopy confirms adequate excision without patella baja. The knee is then closed in layers. RESULTS: Based on existing outcomes of operative management for recalcitrant patellar tendinopathy, the patient is expected to return to her preinjury level of activity with excellent functional outcomes. DISCUSSION/CONCLUSION: Open fragment excision and patellar tendon repair using a double-loaded knotless all-suture anchor is a viable option for treating distal pole patellar nonunion that has failed nonoperative management. PATIENT CONSENT DISCLOSURE STATEMENT: The author(s) attests that consent has been obtained from any patient(s) appearing in this publication. If the individual may be identifiable, the author(s) has included a statement of release or other written form of approval from the patient(s) with this submission for publication.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Modified Multi-Strand Nice Knot Suture Construct Combined with Suture Anchor Fixation Versus Conventional Kirschner Wire Tension Band Fixation for Inferior Patellar Pole Fractures: A Retrospective Comparative Study.Journal of clinical medicine · 2026
- Reconstruction of a 2‑year neglected chronic patellar tendon rupture using peroneus longus autograft with suture anchor and cerclage wire augmentation: A case report and technical note.Medicine · 2026
- Suture anchor and transosseous tunnel repair show no statistically significant differences in functional outcomes after acute patellar tendon rupture in athletes: A retrospective cohort study.Journal of ISAKOS : joint disorders & orthopaedic sports medicine · 2026
- Complex patellar tendon reconstruction using a peroneus longus autograft and structural cortical bone graft after multiple failures: a case report.Journal of surgical case reports · 2026
- A Technique for Patellar Tendon Repair Using a Suture-Free Nonwoven Polyethylene Terephthalate Implant.Arthroscopy techniques · 2026
- Open Repair of Patellar Osteochondral Fracture With Absorbable Sutures.Arthroscopy techniques · 2026