Predicting Interaural Time Difference Sensitivity for Bilateral Cochlear-Implant Listeners From Loudness Levels and Factors Reflective of the Electrode-to-Neural Interface.
Bobby E Gibbs, Miranda Cleary, Joshua G W Bernstein, Matthew J Goupell
Waisman Center, University of Wisconsin-Madison, Madison, WI, USA. · Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA.
Key points
From the paper's conclusion- This study evaluated how interaural-time-difference (ITD) thresholds for bilateral cochlear-implant listeners were related to monaural and binaural factors associated with behavioral loudness perception and objective measures associated with the interface between electrode contacts and target neurons (the electrode-to-neural interface, ENI).
Abstract
This study evaluated how interaural-time-difference (ITD) thresholds for bilateral cochlear-implant listeners were related to monaural and binaural factors associated with behavioral loudness perception and objective measures associated with the interface between electrode contacts and target neurons (the electrode-to-neural interface, ENI). For 11 bilateral cochlear-implant listeners, ITD thresholds for number-matched interaural electrode pairs were measured at five places along the array. On these same electrodes, the most comfortable current level used for stimulation (C-level), electrically evoked compound action potentials (ECAPs), and electrode positions relative to the modiolus based on computed-tomography scans were recorded. Monaural predictors included stimulation level (quantified by C-levels), modiolar distance (related to the width of neural activation), and efficacy of auditory nerve fiber responses to electrical stimulation [ECAP amplitude growth function (AGF) slopes]. Binaural predictors included the degree of interaural asymmetry in both C-levels and modiolar distances. It was hypothesized that better ITD sensitivity would be related to higher C-levels and larger modiolar distances (because of increased loudness and broader neural activation), steeper ECAP AGF slopes (because of more numerous and healthy neurons), and smaller interaural asymmetry (because of a larger proportion of binaurally excited neurons). The hypotheses were tested via backwards elimination in mixed-effects models with bias and stability analyses performed using bootstrapping. Partially confirming the hypotheses, higher C-levels and greater modiolar distance for electrodes in the ear with better ENI (as defined primarily by the ECAP AGF slope) were significantly associated with better ITD thresholds. These results highlight the role of monaural processing in binaural performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrically evoked compound action potentials in adult and pediatric cochlear implant users: I. Cochlear nerve responsiveness and electrode-neuron interface index.Hearing research · 2026
- Rethinking Cochlear Implants: The Need for Precise Temporal Coding.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- The Effect of Etiology, Array Type and Duration of Deafness on Focused Detection Thresholds in Cochlear Implant Listeners.Trends in hearing · 2026
- Improving Spectral Resolution via Simultaneous Extracochlear and Apical Ground Contacts: A Neural Simulation StudyarXiv · 2026
- Contributions of aging, auditory nerve health, and speed of processing to psychophysical gap detection thresholds in cochlear implant users.Hearing research · 2026
- The Interphase Gap Effect in Cochlear Implant Users: Biological Basis, Parameter Selection, Analytical Methods, and Quantitative ScalesJournal of the Association for Research in Otolaryngology · 2026