Auditory Differences in Occupationally Noise-Exposed Workers With Normal Conventional Audiograms: A Multi-Measure Surveillance Approach.
Wulan Zhao, Alexis Pinsonnault-Skvarenina, Meibian Zhang, Zhili Zhang, Hangze Mao, Shixing Bai, Hua Zou, Dan Guo,
School of Medical Technology and Information Engineering, Zhejiang Chinese Medical University, Hangzhou, China. · School of Rehabilitation Sciences, Université Laval, Québec City, QC, Canada.
Key points
From the paper's conclusion- Together, these findings suggest that cochlear-status measures, conventional ARTs, and functional SiN performance provide complementary information beyond the conventional audiogram in occupational hearing surveillance.
Abstract
Young adults with normal conventional audiograms may nonetheless show early noise-related auditory differences that routine surveillance misses. We evaluated a clinically feasible test battery using 280 occupationally noise-exposed workers and 100 age-matched low-noise controls (20-40 years; ≤20 dB HL at 0.5-8 kHz). Measures included conventional and extended high-frequency (EHF; 9-16 kHz) audiometry, distortion-product otoacoustic emissions (DPOAEs; 0.5-10 kHz), ipsilateral acoustic reflex thresholds (ARTs; 0.5, 1, and 2 kHz; 226-Hz probe tone), click-evoked auditory brainstem responses (ABR; wave I, wave V, and V/I ratio at 50 and 90 dBnHL), and Mandarin Bamford-Kowal-Bench speech-in-noise testing (SiN). Noise-exposed participants showed elevated ARTs at all elicitor frequencies, with the largest elevation at 2 kHz, as well as poorer EHF thresholds and lower DPOAE levels. In contrast, click-evoked ABR metrics did not differ between groups. After controlling for conventional-frequency pure-tone average (PTA4; 0.5, 1, 2, and 4 kHz) and extended high-frequency pure-tone average (PTAEHF; 9-16 kHz), lower DPOAE amplitudes were associated with higher ARTs. ARTs were not significantly associated with SiN performance, quantified as the signal-to-noise ratio (SNR) required for 50% correct recognition (SNR-50), cumulative noise exposure, or ABR measures. The noise-exposed group showed higher SNR-50 values, indicating poorer speech-in-noise performance. Within the noise-exposed group, SNR-50 was associated with PTA4 and cumulative noise exposure, whereas its association with PTAEHF was weaker and did not remain significant after correction for multiple comparisons. Together, these findings suggest that cochlear-status measures, conventional ARTs, and functional SiN performance provide complementary information beyond the conventional audiogram in occupational hearing surveillance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Occupational noise effects on hearing thresholds, speech perception, and self-reported hearing abilities in young adult dental hospital personnel.Arhiv za higijenu rada i toksikologiju · 2026
- Broadband Noise Acoustic Stapedial Reflex Thresholds as a Marker of Cochlear and Neural Integrity in Individuals with Normal Audiograms.Audiology research · 2026
- Hearing thresholds among dental professionals and students: early identification of occupational hearing loss using conventional and advanced audiological assessmentsScientific Reports · 2026
- Hyperacusis scores and listening characteristics: Extended high-frequency audiograms from a young population without tinnitus and with low noise exposure.Hearing research · 2026
- Association between occupational noise-induced hearing loss and cognitive function: a multimodal cross-sectional studyFrontiers in Public Health · 2026
- Relationships between extended high frequency hearing, cognition, and speech-in-noise performance.Frontiers in neuroscience · 2026