Journal of applied biomaterials & functional materials

Preliminary in vitro evaluation of biological responses associated with an Elumbotti-derived coating on titanium cortical screws.

Geetha Balasubramani, Premkumar J, Paul Pradeep J

Department of Biomedical Engineering, School of Bio and Chemical Engineering, Sathyabama Institute of Science and Technology, Chennai, India. · MedCuore Medical Solutions Private Limited, Chennai, India.

Preclinical

Key points

From the paper's conclusion
  • Overall, the findings provide preliminary evidence of concentration- and time-dependent biological responses associated with the Elumbotti-derived coating system and its soluble components.

Abstract

The biological response to coating-derived components is an important consideration in the preliminary development of functionalized titanium implants. In the present study, an Elumbotti (Ormocarpum cochinchinense)-derived composite coating was applied to titanium cortical screws (12 mm), and its preliminary in vitro biological response was investigated using a cell-free protein-denaturation assay and MG-63 osteoblast-like cells. Uncoated titanium (T1) and Elumbotti-coated titanium cortical screw samples (ST1) were included in the experimental evaluation. Bovine serum albumin (BSA) protein-denaturation inhibition was assessed as a preliminary cell-free measure of protein-stabilizing activity, with diclofenac sodium used as the reference standard. MG-63 cellular responses were evaluated using MTT viability, scratch-wound closure, and acridine orange/ethidium bromide (AO/EtBr) fluorescence staining assays. The MTT assay evaluated concentration-dependent responses to the ST1 test preparation, whereas the scratch-wound and AO/EtBr assays evaluated cellular responses following exposure to conditioned medium obtained from ST1-coated titanium cortical screws. ST1 demonstrated greater BSA protein-denaturation inhibitory activity than T1, with calculated IC50 values of 63.032 and 118.379 µg/mL, respectively. In the MTT assay, MG-63 viability showed a concentration-dependent response to the ST1 test preparation, remaining above 70% at concentrations up to 32 µg/mL and decreasing below 70% at concentrations of 64 µg/mL and above. Scratch-wound closure following exposure to ST1-conditioned medium increased from 67.07% at 24 h to 83.45% at 48 h, compared with 27.24% and 34.50%, respectively, in untreated control cells. AO/EtBr staining demonstrated time-dependent changes in cell viability and membrane integrity following prolonged exposure to ST1-conditioned medium. Overall, the findings provide preliminary evidence of concentration- and time-dependent biological responses associated with the Elumbotti-derived coating system and its soluble components. However, the present assays do not establish direct cell-coating interactions, cellular anti-inflammatory activity, osteogenic differentiation, osseointegration, or improved orthopedic implant performance. Further batch-specific physicochemical characterization, direct cell-surface studies, coating stability and release analyses, osteogenic and inflammatory-marker evaluation, and in vivo investigation are required to establish the biological and functional relevance of the coating for orthopedic applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers