Anterior-Only Stabilization of Traumatic Subaxial Cervical Spine Injuries: Why Constructs Fail and Why Most Survive-A Systematic Review.
Deya Alwady, Mohamed M Aly, Richard Bransford, Andrei Joaquim, Bogdan Costachescu, Eugen Cezar Popescu, Abdulaziz Bin Shebreen, Saleh Baeesa,
Centre for Spinal Studies and Surgery, Queen's Medical Centre, Nottingham University Hospitals NHS Trust, Nottingham, UK. · Department of Neurosurgery, Mansoura University, Mansoura, Egypt.
Key points
From the paper's conclusion- We propose a hypothesis-generating construct-survival framework balancing mechanical demand against construct capacity until fusion and requiring prospective validation.
Abstract
Study DesignSystematic review.ObjectivesTo characterize mechanical failure rates and candidate risk signals for failure after anterior-only stabilization for traumatic subaxial cervical spine injuries.MethodsWe searched MEDLINE, Embase, Scopus, Web of Science, and the Cochrane Central Register of Controlled Trials from inception to June 1, 2026 for studies evaluating mechanical construct failure or candidate risk signals after anterior-only stabilization for subaxial fractures. Narrative synthesis reported crude event fractions and study-specific odds ratios without pooling. Risk of bias and evidence certainty were assessed using ROBINS-I and GRADE (PROSPERO CRD420261420216).ResultsSix studies were included: five retrospective clinical cohorts (659 patients) and one nationwide registry (1,486 patients). Crude failure fractions were 5.8% (38/659) overall and 8.1% (33/405) in a morphology-focused descriptive subset, excluding separable stiff-spine cases. The separately analyzed registry recorded implant failure in 0.9% (14/1,486), implant malposition in 1.0% (15/1,486). Candidate risk signals included posterior tension-band injury (bilateral facet dislocation, posterior longitudinal ligament [PLL] injury, and facet fracture), compression endplate fracture, older age, and C7-T1 involvement; AO Spine Type C morphology was associated with registry implant failure. Compression endplate fracture and older age were each associated with failure in two cohorts; the remaining signals in one. In three cohorts with specific timing, failures were identified within seven postoperative weeks. Evidence certainty was very low.ConclusionsMechanical failure appears uncommon in selected anterior plate-based cohorts. Each candidate risk signal was supported by one or two studies; effects may depend on patient selection and surgical technique. We propose a hypothesis-generating construct-survival framework balancing mechanical demand against construct capacity until fusion and requiring prospective validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early catastrophic posterior migration of a cervical disc replacement polyethylene insert resulting in complete spinal cord injury: illustrative case.Journal of neurosurgery. Case lessons · 2026
- Mechanical complication patterns following cervical and cervicothoracic junction en bloc spondylectomy of primary spinal tumors: a single-institution decade of experience.Journal of neurosurgery. Spine · 2026
- Comparative risk of instrumentation failure in dynamic and rigid spinal stabilization: a propensity-matched cohort study.Neurosurgical review · 2026
- Risk factors for mechanical failure involving the cervicothoracic junction following posterior cervical instrumentation.Journal of neurosurgery. Spine · 2026
- Anterior Arch Fracture of the Atlas on Postoperative Day 6 Following Unilateral C1 Laminectomy Requiring Occiput-to-C2 Fusion: A Case Report.Cureus · 2026
- Unilateral versus bilateral posterior C1 lateral mass-C2 pedicle screw fixation for traumatic odontoid fractures: a retrospective comparative cohort study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026