Evaluating effects of a new hip-knee-ankle-foot orthosis on gait parameters in healthy individuals.
Kourosh Barati, Shahrbanoo Bidari, Mohammad Hadadi, Mohammadtaghi Karimi, Mahziyar Darvishi, Amin Komeili
Department of Orthotics and Prosthetics, School of Paramedical and Rehabilitation Sciences, Mashhad University of Medical Sciences, Mashhad, Iran. · Orthopedic & Rehabilitation Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
Key points
From the paper's conclusion- In healthy participants, the Multiflex HKAFO permitted greater motion in selected hip and ankle planes than the conventional design while producing lower center-of-pressure velocity and mediolateral excursion in some configurations.
Abstract
BACKGROUND: Hip-knee-ankle-foot orthoses (HKAFOs) are commonly used to assist gait; however, conventional designs are associated with high energy expenditure and poor mediolateral balance. OBJECTIVE: This pilot study examined whether permitting additional motion in selected hip and ankle planes altered joint kinematics and dynamic-balance parameters in healthy participants. STUDY DESIGN: A randomized cross-over trial was conducted with 20 healthy participants aged 18-25. METHODS: Gait performance was evaluated under five conditions: conventional HKAFO (locked/unlocked knee), Multiflex HKAFO (locked/unlocked knee), and no orthosis. Kinematic and balance data were collected. Key variables analyzed included center of pressure (CoP) velocity, mediolateral sway, and joint range of motion (ROM). RESULTS: Compared with the conventional HKAFO configurations, the Multiflex HKAFO permitted greater abduction/adduction and ankle inversion/eversion ROM. With the Multiflex HKAFO and an unlocked knee joint, CoP velocity and mediolateral excursion were not significantly different from walking without an orthosis. However, knee flexion/extension and ankle dorsiflexion/plantarflexion remained restricted relative to walking without an orthosis. CONCLUSION: In healthy participants, the Multiflex HKAFO permitted greater motion in selected hip and ankle planes than the conventional design while producing lower center-of-pressure velocity and mediolateral excursion in some configurations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ankle-Foot Orthosis and Footwear Interactions in Adult Healthy and Patient Populations: Systematic Review of Biomechanical Outcomes.JMIR rehabilitation and assistive technologies · 2026
- Comparing Ankle Dorsiflexion-Only, Hip Flexion-Only, and Combined Hip-Ankle Assistance During Simulated Foot Drop Gait.IEEE transactions on bio-medical engineering · 2026
- An Active Knee–Ankle–Foot Orthosis With Torque‐Dense, Low‐Impedance Knee ActuationAdvanced Intelligent Systems · 2026
- Effects of stiffness-optimized ankle-foot orthoses on gait stability in people with calf muscle weakness - An exploratory study.Journal of biomechanics · 2026
- An Adaptive Knee Brace Is Associated With Improved Dynamic Stabilization Compared With a Standard Passive Brace in Anterior Cruciate Ligament-Deficient Men During a Functional Hop Task.Arthroscopy, sports medicine, and rehabilitation · 2026
- Non-Weightbearing in Hinged-Knee Braces Locked in High Degrees of Flexion Shows High Hamstring Muscle Activation in Healthy Volunteers.Arthroscopy, sports medicine, and rehabilitation · 2026