Digital health

Head-to-head evaluation of large language models for automated risk of bias assessment in randomized controlled trials: A two-phase diagnostic study with meta-reanalysis.

Jia-Jun Cheng, Fu-Qiang Wang, Zhang-Yi Dai, Zhi-Yang Li, Xiang-Chao Kong, Xin-Wei Wang, Han-Lu Zhang, Yun Wang

Department of Thoracic Surgery, West China Hospital, Sichuan University, Chengdu, China. · Department of Lung Cancer, Tianjin Lung Cancer Center, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China.

Key points

From the paper's conclusion
  • LLMs demonstrated high diagnostic accuracy (binary accuracy: 89.3%; ternary accuracy: 87.5%) and reduced assessment time by approximately 16 minutes per RCT compared with manual evaluation. However, both models showed limited ability to reliably distinguish "Some concerns" from "High risk" judgments, and performance depended on post-hoc chain-of-thought prompt optimization. These findings indicate that LLMs are not yet suitable for fully autonomous bias assessment and should be deployed as adjunctive tools, with human oversight retained for final judgments.

Abstract

OBJECTIVE: Large language models (LLMs) are emerging as promising tools in medical research, yet their feasibility for automating risk-of-bias assessment in systematic reviews and meta-analyses (SR/MAs) remains underexplored. To this end, we systematically evaluated the accuracy, consistency, and efficiency of two representative LLMs in conducting Cochrane Risk of Bias 2 (RoB-2) assessments, through a head-to-head comparison integrated with a two-phase analytical design that introduced post-hoc chain-of-thought prompt optimization to mirror the human adjudication process. A subsequent meta-reanalysis further traced the downstream impact of LLM-flagged high-risk-of-bias judgments on the robustness of pooled evidence. METHODS: In a two-phase diagnostic study design, two representative LLMs (LLM-1, open-source; LLM-2, commercial) assessed 56 randomized controlled trials (RCTs) from five systematic reviews and meta-analyses. Standard RoB-2based prompts were refined post hoc through chain-of-thought prompting to mitigate overly risk-averse ratings. LLM assessments were compared against human reference standards from the original reviews. Performance was quantified via confusion matrices, accuracy, F1-score, Matthews Correlation Coefficient (MCC), and Cohen's kappa. RESULTS: In post-hoc analysis, binary classification accuracy reached 86.8% (LLM-1) and 89.3% (LLM-2); ternary accuracy reached 85.7% and 87.5%, respectively. MCC exceeded 0.6 for both models, and inter-model kappa improved to 0.601, indicating moderate to high consistency. LLMs reduced assessment time by approximately 16 minutes per RCT compared with manual evaluators. Excluding LLM identified high risk RCTs in meta reanalysis strengthened evidence robustness without altering effect directions. CONCLUSION: LLMs demonstrated high diagnostic accuracy (binary accuracy: 89.3%; ternary accuracy: 87.5%) and reduced assessment time by approximately 16 minutes per RCT compared with manual evaluation. However, both models showed limited ability to reliably distinguish "Some concerns" from "High risk" judgments, and performance depended on post-hoc chain-of-thought prompt optimization. These findings indicate that LLMs are not yet suitable for fully autonomous bias assessment and should be deployed as adjunctive tools, with human oversight retained for final judgments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers