Performance and Safety of a Continuous Glucose Monitoring System in Pregnant Women With Gestational Diabetes Mellitus: A Multicenter, Open-Label Trial
Jie Shen, Huiling Shang, Weiwei Zhu, Maudline Abra Novihoho
Foshan Maternity and Child Health Care Hospital
Key points
From the paper's conclusion- The CGM system demonstrated accurate, stable, and safe glucose monitoring over 15 days in pregnant women with predominantly GDM. Its strong performance supports its utility as a reliable tool for glucose monitoring during pregnancy.
Abstract
BACKGROUND: Continuous glucose monitoring (CGM) is increasingly important in pregnancies complicated by diabetes, where strict glycemic control is essential to prevent adverse outcomes such as fetal macrosomia and preterm birth. In gestational diabetes mellitus (GDM)-which accounts for most of the diabetes in pregnancy-maternal hyperglycemia is the primary clinical concern. This study evaluated the accuracy and safety of a factory-calibrated CGM system over 15 days in pregnant women with diabetes, with most having GDM. METHODS: This prospective, multicenter, open-label trial enrolled 60 pregnant women (95% GDM, 3.3% type 1 diabetes, 1.7% type 2 diabetes). Each participant wore 2 sensors simultaneously, 1 on each upper arm, for up to 15 days. Venous blood glucose reference values were obtained using a Biosen C-line GP+ analyzer. Accuracy was assessed by 20/20% agreement rate, Diabetes Technology Society (DTS) error grid analysis, and mean absolute relative difference (MARD). Safety and usability were also evaluated. RESULTS: A total of 2901 matched CGM-reference pairs were analyzed (1451 from left-arm sensors, 1450 from right-arm sensors). The 20/20% agreement rate was 96.6% (95% CI, 95.6%-97.5%) for the left arm and 96.8% (95% CI, 95.8%-97.7%) for the right arm. The overall MARD was 7.72% (95% CI, 7.33%-8.11%) for the left arm and 7.66% (95% CI, 7.27%-8.05%) for the right arm. CONCLUSION: The CGM system demonstrated accurate, stable, and safe glucose monitoring over 15 days in pregnant women with predominantly GDM. Its strong performance supports its utility as a reliable tool for glucose monitoring during pregnancy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparing efficacy in glycaemic control and pregnancy outcomes between continuous glucose monitoring and self-monitoring of blood glucose in pregnancies complicated by gestational diabetes mellitus: a systematic review and meta-analysis.Diabetes research and clinical practice · 2026
- A systematic review and meta-analysis of the effects of continuous glucose monitoring compared to self-monitoring of blood glucose on glycemic control and maternal and infant outcomes in women with gestational diabetes mellitus.BMC pregnancy and childbirth · 2026
- Continuous Glucose Monitoring in Gestational Diabetes Mellitus: Evidence, Clinical Benefits and Remaining Challenges.Diabetes therapy : research, treatment and education of diabetes and related disorders · 2026
- Comparative Effectiveness of Continuous Glucose Monitoring Versus Blood Glucose Monitoring in Pregnancy With Diabetes: Systematic Review and Meta-analysis With Trial Sequential Analysis.Diabetes, obesity, and cardiometabolic CARE · 2026
- Continuous glucose monitoring in early gestational diabetes improves maternal and neonatal outcomes—The Steady Sugar trialDiabetes Obesity and Metabolism · 2025
- Accuracy, safety, and usability of a real-time continuous glucose monitoring system in pediatric diabetes management.Journal of diabetes investigation · 2026