A quantitative trigger model to enable personalized adaptive radiotherapy in nasopharyngeal carcinoma.
Xiao-Li Yu, Jiang Hu, Wen-Chao Diao, Guang-Yu Wang, Xin Yang, Lu Liu, Xiao-Bo Jiang, Chen-di Xu,
Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in Southern China, Collaborative Innovation Center of Cancer Medicine, Guangzhou, China. · Research Cooperation Department, Shenzhen United Imaging Research Institute of Innovative Medical Equipment, Shenzhen, China.
Key points
From the paper's conclusion- We developed and validated a transparent, quantitative trigger model integrating clinical expertise with quantified volumetric/dosimetric changes and structural prioritization to enable individualized ART decision-making for NPC. This model supports automated, real-time ART triggering with adjustable thresholds, adaptable to imaging frequencies, and customizable to institutional practice. However, multicenter or prospective validation is still warranted before widespread clinical adoption.
Abstract
BACKGROUND: Adaptive radiotherapy (ART) is increasingly used for nasopharyngeal carcinoma (NPC), yet optimal triggers remain undefined. OBJECTIVES: This study developed a quantitative trigger model integrating clinical expertise with morphological and dosimetric changes during treatment to support personalized, scalable ART decision-making. DESIGN: This was a single-center, retrospective cohort study conducted at Sun Yat-sen University Cancer Center. METHODS: Between 2022 and 2024, 60 NPC patients treated on an integrated ART platform (uRT-linac 506c) were enrolled. Forty patients who underwent ART at least once during radiotherapy constituted the training set; morphological and dosimetric parameters between the original treatment plan and fractional radiotherapy were quantified, weighted, and modeled using clinician-simulated ART timing as the reference. The remaining 20 patients (17 with ART and 3 without) served as the validation set. RESULTS: A total of 1,466 fan-beam CT scans from 60 patients (40 training, 20 validation) were analyzed. A weighted Trigger Score (TS) was developed, combining volumetric and dosimetric scores in target volumes and key organs-at-risk (parotids, submandibular glands, thyroid, brainstem, spinal cord, optic nerves, chiasm, and temporal lobes). Two trigger modes were defined: 1) an absolute TS ≥65 points, or 2) a TS change ratio ≥1.5 (=TS_y × (y - 2)/Σ TS_2: TS_(y-1), where y = fraction number). In the validation cohort, the model showed high concordance with clinician-simulated triggers, achieving ROC-AUCs of 0.879 (daily) and 0.872 (weekly). The model has been integrated into our clinical ART platform for operational use. CONCLUSION: We developed and validated a transparent, quantitative trigger model integrating clinical expertise with quantified volumetric/dosimetric changes and structural prioritization to enable individualized ART decision-making for NPC. This model supports automated, real-time ART triggering with adjustable thresholds, adaptable to imaging frequencies, and customizable to institutional practice. However, multicenter or prospective validation is still warranted before widespread clinical adoption.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Predicting the benefit of adaptive radiotherapy in head and neck Cancer using cone-beam computed tomography.Physics and imaging in radiation oncology · 2026
- Integrating radiomics and dosiomics to predict tumor regression for early adaptive radiotherapy in NSCLC patients.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- A simple and interpretable method to predict head and neck offline adaptation needs based on anatomical changesMedical Physics · 2026
- A clinical evaluation of HyperSight CBCT enhanced offline adaptive breast radiotherapy.Frontiers in oncology · 2026
- Impacts of volumetric vs. anatomical accuracies in GTV segmentation for nasopharyngeal carcinoma: a consensus-guideline-based study.Frontiers in medicine · 2026
- Overlap-adapted Subvolume Prescription to Reduce Temporal Lobe Injury Risk in T4 Nasopharyngeal Carcinoma: A Prospective Cohort Study with a Contemporaneous Comparator.Practical radiation oncology · 2026