Therapeutic advances in medical oncology

A quantitative trigger model to enable personalized adaptive radiotherapy in nasopharyngeal carcinoma.

Xiao-Li Yu, Jiang Hu, Wen-Chao Diao, Guang-Yu Wang, Xin Yang, Lu Liu, Xiao-Bo Jiang, Chen-di Xu,

Department of Radiation Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in Southern China, Collaborative Innovation Center of Cancer Medicine, Guangzhou, China. · Research Cooperation Department, Shenzhen United Imaging Research Institute of Innovative Medical Equipment, Shenzhen, China.

Observational · n=60

Key points

From the paper's conclusion
  • We developed and validated a transparent, quantitative trigger model integrating clinical expertise with quantified volumetric/dosimetric changes and structural prioritization to enable individualized ART decision-making for NPC. This model supports automated, real-time ART triggering with adjustable thresholds, adaptable to imaging frequencies, and customizable to institutional practice. However, multicenter or prospective validation is still warranted before widespread clinical adoption.

Abstract

BACKGROUND: Adaptive radiotherapy (ART) is increasingly used for nasopharyngeal carcinoma (NPC), yet optimal triggers remain undefined. OBJECTIVES: This study developed a quantitative trigger model integrating clinical expertise with morphological and dosimetric changes during treatment to support personalized, scalable ART decision-making. DESIGN: This was a single-center, retrospective cohort study conducted at Sun Yat-sen University Cancer Center. METHODS: Between 2022 and 2024, 60 NPC patients treated on an integrated ART platform (uRT-linac 506c) were enrolled. Forty patients who underwent ART at least once during radiotherapy constituted the training set; morphological and dosimetric parameters between the original treatment plan and fractional radiotherapy were quantified, weighted, and modeled using clinician-simulated ART timing as the reference. The remaining 20 patients (17 with ART and 3 without) served as the validation set. RESULTS: A total of 1,466 fan-beam CT scans from 60 patients (40 training, 20 validation) were analyzed. A weighted Trigger Score (TS) was developed, combining volumetric and dosimetric scores in target volumes and key organs-at-risk (parotids, submandibular glands, thyroid, brainstem, spinal cord, optic nerves, chiasm, and temporal lobes). Two trigger modes were defined: 1) an absolute TS ≥65 points, or 2) a TS change ratio ≥1.5 (=TS_y × (y - 2)/Σ TS_2: TS_(y-1), where y = fraction number). In the validation cohort, the model showed high concordance with clinician-simulated triggers, achieving ROC-AUCs of 0.879 (daily) and 0.872 (weekly). The model has been integrated into our clinical ART platform for operational use. CONCLUSION: We developed and validated a transparent, quantitative trigger model integrating clinical expertise with quantified volumetric/dosimetric changes and structural prioritization to enable individualized ART decision-making for NPC. This model supports automated, real-time ART triggering with adjustable thresholds, adaptable to imaging frequencies, and customizable to institutional practice. However, multicenter or prospective validation is still warranted before widespread clinical adoption.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A quantitative trigger model to enable personalized adaptive radiotherapy in nasopharyngeal carcinoma — Science Skim