Diagnostic accuracy of peak vein velocity ratio for innominate vein stenosis in haemodialysis patients with long-term non-cuffed right internal jugular catheters.
Dedy Pratama, Ali Satria, Dewi S Soemarko, Fakhri M Zaidan, Muhammad F Ferian
Division of Vascular and Endovascular Surgery, Department of Surgery, Faculty of Medicine, University of Indonesia - Cipto Mangunkusumo General Hospital, Central Jakarta, Indonesia. · Department of Community Medicine, Faculty of Medicine, University of Indonesia, Central Jakarta, Indonesia.
Key points
From the paper's conclusion- Peak vein velocity ratio shows high sensitivity and negative predictive value as a screening tool for catheter-related innominate vein stenosis. A cutoff of 1.65 makes significant stenosis unlikely when not exceeded, supporting a possible role as a non-invasive triage step before venography in resource-limited settings, pending external validation.
Abstract
OBJECTIVE: To evaluate the diagnostic accuracy of ultrasound-derived peak vein velocity ratio for detecting central vein stenosis in the innominate vein resulting from long-term non-cuffed double-lumen haemodialysis catheters. METHODS: A cross-sectional study was conducted on haemodialysis patients with right internal jugular vein catheters. All subjects underwent duplex ultrasound to calculate peak vein velocity ratio, defined as the ratio of peak velocity in the innominate vein to the pre-stenotic internal jugular vein. Venography was performed as the gold standard. RESULTS: Of 50 patients analysed, innominate vein stenosis prevalence was 68%. Diabetes mellitus was significantly associated with stenosis (odds ratio = 5.16; p = 0.049). An innominate-to-internal jugular vein peak vein velocity ratio cutoff of ⩾1.65 identified innominate vein stenosis (>30% luminal narrowing) with 97.1% sensitivity, 56.2% specificity, and an area under the curve of 0.71. CONCLUSION: Peak vein velocity ratio shows high sensitivity and negative predictive value as a screening tool for catheter-related innominate vein stenosis. A cutoff of 1.65 makes significant stenosis unlikely when not exceeded, supporting a possible role as a non-invasive triage step before venography in resource-limited settings, pending external validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasound-derived Hemodynamic Parameters for Predicting Presence and Site of Arteriovenous Fistula Stenosis.Journal of vascular and interventional radiology : JVIR · 2026
- Doppler Ultrasound-Derived Blood Flow Parameters Associated with Significant Arteriovenous Fistula Stenosis in a Large Vietnamese Hemodialysis Cohort.Vascular health and risk management · 2026
- Preserving the Dialysis Lifeline: An Updated Review on Central Venous StenosisJournal of Vascular Diseases · 2026
- Nursing Ultrasound Monitoring of Arteriovenous Fistulas in Haemodialysis: The ECHO‐NURSE StudyJournal of Renal Care · 2026
- NON-INVASIVE HemodynamicS of Non-Thrombotic Iliac Vein Lesions ARE DISTURBED IN PATIEnTS with A HiSTORY OF Deep Venous Thrombosis.Journal of vascular surgery. Venous and lymphatic disorders · 2026
- Use of Renal Duplex To Detect Renal Artery Stenosis in Fibromuscular Dysplasia.medRxiv : the preprint server for health sciences · 2026