Automated surveillance of primary outcome reporting in clinical trials: Development and validation of a scalable screening pipeline.
Hayden Farquhar
Independent Researcher, Finley, NSW, Australia.
Key points
From the paper's conclusion- The pipeline processed 46,365 trials in under 48 h, matching 27,555 (59.4%) to publications and confirming 13,595 pairs via trial identifier verification. Automated screening classified 10,231 (75.3%) as concordant and flagged 3353 (24.7%) for review. Against manual review of 123 pairs, the screen achieved 100% specificity and 16.7% sensitivity (1 of 6 discrepancies); the flag's positive predictive value could not be estimated because the validation sample contained only one flagged pair. Independent large language model re-review showed 99.2% agreement (Cohen's kappa = 0.91). Manual review estimated a true discrepancy rate of 4.9% (95% confidence interval = 1.6%-8.9%), predominantly minor modifications (timeframe extensions, operationalisation changes) rather than substantive outcome switching. Automated flag rates were not associated with primary outcome statistical significance (21.0% vs 20.6%; p = 0.745).
Abstract
BACKGROUND: Detecting discrepancies between registered and published trial outcomes currently requires manual expert review, limiting surveillance to small samples. No scalable automated system exists for continuous monitoring of outcome reporting integrity across the clinical trial literature. We aimed to develop and validate an automated screening pipeline for primary outcome discrepancies and to characterise its performance at scale. METHODS: We developed an automated pipeline that retrieves trial registrations from ClinicalTrials.gov, matches them to publications via PubMed and screens for primary outcome discrepancies using a term-matching algorithm. We applied the pipeline to all 46,365 completed interventional trials with posted results (2015-2025) and validated performance against manual expert review of 123 trial-publication pairs, with independent large language model re-review as a second rater. RESULTS: The pipeline processed 46,365 trials in under 48 h, matching 27,555 (59.4%) to publications and confirming 13,595 pairs via trial identifier verification. Automated screening classified 10,231 (75.3%) as concordant and flagged 3353 (24.7%) for review. Against manual review of 123 pairs, the screen achieved 100% specificity and 16.7% sensitivity (1 of 6 discrepancies); the flag's positive predictive value could not be estimated because the validation sample contained only one flagged pair. Independent large language model re-review showed 99.2% agreement (Cohen's kappa = 0.91). Manual review estimated a true discrepancy rate of 4.9% (95% confidence interval = 1.6%-8.9%), predominantly minor modifications (timeframe extensions, operationalisation changes) rather than substantive outcome switching. Automated flag rates were not associated with primary outcome statistical significance (21.0% vs 20.6%; p = 0.745). DISCUSSION: Automated screening can efficiently triage tens of thousands of trials for outcome reporting surveillance, deprioritising 75% of pairs as concordant and concentrating manual review on the flagged subset. The pipeline provides a foundation for continuous, near-real-time monitoring of outcome reporting integrity that could be integrated into journal peer review or regulatory workflows.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An automated approach to improve clinical trial registration and to identify outcome changes on ClinicalTrials.gov.NPJ digital medicine · 2026
- TrialScout links published results to trial registrations using a large language modelmedRxiv · 2026
- An LLM-assisted Pipeline for Identifying ClinicalTrials.gov Registry Changes and Their Association with Primary Endpoint PositivitymedRxiv · 2026
- Kurate: Scalable Scientific Quality AnalysisarXiv · 2026
- Core open science practices in major medical journals: development of an automatized tool based on a Large Language Model.Open research Europe · 2026
- MechaScreener: Large language model-based automated screening for systematic reviews and research.Research synthesis methods · 2026