Hand (New York, N.Y.)

Distal Interphalangeal Joint Arthrodesis: A Systematic Review of 3 Common Fixation Techniques.

Ayesh Ali, Hamza Khalid, Luke McCarron, Brahman S Sivakumar, David J Graham

University of New England, Armidale, NSW, Australia. · University of Newcastle, Callaghan, NSW, Australia.

Meta-analysis

Key points

From the paper's conclusion
  • This study reviews the outcomes of distal interphalangeal (DIP) and thumb interphalangeal (IP) joint arthrodesis using 3 fixation techniques.

Abstract

This study reviews the outcomes of distal interphalangeal (DIP) and thumb interphalangeal (IP) joint arthrodesis using 3 fixation techniques. A systematic review and meta-analysis were conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Five databases were queried through to February 2025. Studies reporting outcomes following DIP or thumb IP joint arthrodesis using Kirschner wires (K-wires), headless compression screws (HCS), or the X-Fuse intramedullary implant were included. Data on fusion rates, patient demographics, reoperations, and nonoperative complications were extracted and analyzed using a single-arm meta-analysis with subgroup comparisons based on technique. Thirty-one studies involving 1022 patients and 1507 procedures were included. Pooled mean patient age was 57.87 ± 13.97 years, with 74% female participants. Mean follow-up was 17.75 ± 23.90 months. The overall fusion rate was 93% (95% CI: 90%-95%; I2 = 35%), with the highest fusion rate in the X-Fuse subgroup at 96% (95% CI: 88%-98%), followed by HCS at 94% (95% CI: 90%-96%) and K-wire fixation at 90% (95% CI: 86%-92%). The pooled reoperation rate was 6.3%, most commonly for removal of symptomatic hardware or revision of nonunions. Nonoperative complications occurred in 9.3% of cases, primarily involving paresthesia and subungual hemorrhage. Mean postoperative visual analog pain score was 0.74 ± 1.02. DIP and thumb IP arthrodesis provide high fusion rates and meaningful pain relief, with newer fixation methods like the X-Fuse demonstrating slightly improved outcomes. Further comparative studies with longer follow-ups are needed to determine the optimal fixation technique.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Distal Interphalangeal Joint Arthrodesis: A Systematic Review of 3 Common Fixation Techniques — Science Skim