Reliability and Feasibility of Custom-Developed Water Displacement Device for Arm Volume Measurement.
Caroline Lilja, Frederik Christopher Gulmark Hansen, Jens Ahm Sørensen, Jørn Bo Thomsen
Research Unit for Plastic Surgery, Odense University Hospital, Odense, Denmark.
Key points
From the paper's conclusion- Our custom-developed water displacement device is a reliable tool for measuring arm volume of healthy persons, despite a slight overestimation compared with Bravometer.
Abstract
INTRODUCTION: Accurate arm volume measurements are crucial for monitoring treatment and progression of breast cancer-related lymphedema. Water displacement volumetry was recently identified as a valid reference test for measuring lymphedema volume. Discontinuation of the production of Bravometer, a water displacement device, led to the creation of our own water volumetry device. This study aimed to evaluate the feasibility and reliability compared with the Bravometer. METHOD: In this study, two investigators measured arm volume in healthy volunteers using Bravometer (Device A) and our custom-made device (Device B). Each participant's arm volume was measured three times by both investigators using both devices. Intra- and inter-rater reliability as well as inter-device agreement was assessed using the intraclass correlation coefficient (ICC). RESULTS: Thirty arms were included. Device A and Device B demonstrated almost perfect agreement, with overall ICCs of 0.995 [0.991; 0.997] for Device A and 0.994 [0.989; 0.996] for Device B. Intra-rater ICCs for Device A were 0.995 [0.992; 0.998] for Rater 1 and 0.997 [0.994; 0.998] for Rater 2. For Device B, the ICCs were 0.994 [0.989; 0.997] and 0.998 [0.996; 0.999] for Rater 1 and 2, respectively. Inter-rater ICCs were 0.994 [0.989; 0.997] for Device A and 0.992 [0.985; 0.996] for Device B. Device B consistently measured 66.150 mL higher than Device A. Limits of agreement for Device A ranged from -63.4 mL to 74.9 mL and from -84.4 mL to 89.3 mL for Device B. CONCLUSIONS: Our custom-developed water displacement device is a reliable tool for measuring arm volume of healthy persons, despite a slight overestimation compared with Bravometer.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Repeatability of upper limb volume measurements based on the Kuhnke measurement protocol and frustum volume calculation in women after unilateral mastectomy: a cross-sectional methodological studyScientific Reports · 2026
- Lower limb lymphedema: reliability of four non-imaging measurement modalities.Disability and rehabilitation · 2026
- Non-invasive near-infrared measurement of blood concentration in chest tube output: a proof-of-concept study.Biomedical physics & engineering express · 2026
- Validation of the Swedish Lymphedema Functioning, Disability, and Health (Lymph-ICF-UL) Questionnaire: A cross-cultural psychometric study.Scandinavian journal of surgery : SJS : official organ for the Finnish Surgical Society and the Scandinavian Surgical Society · 2026
- Agreement between upper-arm and wrist cuff occlusion for the assessment of vascular reactivity by digital thermal monitoring.Frontiers in physiology · 2026
- Objective Severity, Pain and Range-of-Motion Limitation in Breast Cancer-Related Upper-Limb Lymphedema: Associations with Patient-Reported Burden.Journal of clinical medicine · 2026