Deep-Learning Enhanced Augmented Reality for Robotic Radical Prostatectomy on Consumer Grade Hardware.
Vincent Benard, Olivier Windisch, Mina Bjelogrlic, Hugues Turbé, Christian Lovis, Michele Diana, Massimo Valerio
Department of Urology, University Hospitals of Geneva, Geneva, Switzerland. · Division of Medical Information Sciences, University Hospitals of Geneva, Geneva, Switzerland.
Key points
From the paper's conclusion- On the surgical console, photon-to-photon median latency increased from 60 ms (Q1-Q3: 57.5-62.5) to 120.5 ms (Q1-Q3: 111-131) with the AR pipeline.ConclusionsReal-time AR-RARP with DL-based desocclusion is achievable on low-cost hardware with an added latency remaining within ranges reported as technically acceptable for intraoperative use.
Abstract
BackgroundAugmented Reality (AR) during Robotic-Assisted Radical Prostatectomy (RARP) provides surgical guidance by overlaying patient-specific 3D Virtual Models (VM) onto the intraoperative view. A main drawback is instrument occlusion, where VM overlaps the surgical tools, disturbing the augmented view. Deep learning (DL)-based desocclusion addresses this issue, but current implementation rely on expensive, specialized hardware.MethodsWe developed an AR desocclusion pipeline running on consumer-grade hardware (∼1150 US Dollars). For model selection, we trained and benchmarked 21 encoder architectures paired with a U-Net decoder. The selected model was integrated into a macOS application using CoreML inference on the Apple Neural Engine. Memory usage, thermal state and framerate were monitored on a continuous 81-minute console session. Photon-to-photon latency (from surgical field to the surgeon eye) was measured on the DaVinci® Xi using a microcontroller-phototransistor setup.ResultsFastViT-S12/Unet offered the highest accuracy among models meeting our inference-time budget (∼2 ms inference), achieving a Dice score of 95.1% (95% CI, 94.3-95.7) internally, 91.6% (95% CI, 90.2-92.9) and 90.2% (95% CI, 84.7-94.4) on externals tests, with a mean inference time of 1.89 ± 0.36 ms. The pipeline maintained 57.98 frames per second using 1.47 GB of unified memory with a nominal thermal state. On the surgical console, photon-to-photon median latency increased from 60 ms (Q1-Q3: 57.5-62.5) to 120.5 ms (Q1-Q3: 111-131) with the AR pipeline.ConclusionsReal-time AR-RARP with DL-based desocclusion is achievable on low-cost hardware with an added latency remaining within ranges reported as technically acceptable for intraoperative use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MedMLX: On-Device Medical Imaging AI for Apple SiliconmedRxiv · 2026
- Adaptive Deep Video Frame Interpolation for Robust Laparoscopic Visualization: A Comparative EvaluationInternational Journal of Imaging Systems and Technology · 2026
- SurgFusion-Net: Diversified Adaptive Multimodal Fusion Network for Surgical Skill Assessment.IEEE transactions on medical imaging · 2026
- Artificial Intelligence‐Based Recognition of the Prostatic Capsule During Nerve‐Sparing Robot‐Assisted Radical ProstatectomyInternational Journal of Urology · 2026
- RetiDual-Select: Reliability-Aware Specialist-Generalist Routing for Retinal OCT under Image-Quality ShiftarXiv · 2026
- Deep Learning Approach for Pulmonary Orientation Detection: Toward Automated Intraoperative Imaging Guidance.Innovations (Philadelphia, Pa.) · 2026