Flow Diversion for a Cervical Internal Carotid Artery Aneurysm: A Case Report and Literature Review.
Camila Esquetini-Vernon, Sukhwinder Johnny Singh Sandhu, Richard D Beegle, Rabih Tawk, Young Erben
Division of Vascular and Endovascular Surgery, Mayo Clinic, Jacksonville, FL, USA. · Division of Neuroradiology, Mayo Clinic, Jacksonville, FL, USA.
Key points
From the paper's conclusion- At 12 months, she is asymptomatic with a 70% reduction in the contrast-opacified aneurysm component to 7 mm, and the contralateral small aneurysm remains stable.ConclusionFlow diversion with a PED provided an effective, artery-preserving solution for a mid-cervical ICA aneurysm in tortuous anatomy, achieving immediate flow stasis with parent-artery patency.
Abstract
IntroductionExtracranial internal carotid artery (ICA) aneurysms are rare (<1% of arterial aneurysms) yet clinically significant due to risks of distal embolization, local compressive symptoms, and, less commonly, rupture. High-quality evidence is limited, and no consensus guidelines exist, management is therefore individualized to aneurysm morphology, cervical segment involvement, vessel tortuosity, and operator expertise. Flow diversion with Pipeline Embolization Device (PED) achieves aneurysm exclusion while reconstructing the parent artery and is especially useful in tortuous cervical segments.Clinical SummaryA 60-year-old woman with incidentally discovered bilateral cervical ICA aneurysms (left 2.3 cm mid-ICA; right 0.5 cm) and a type III bovine arch underwent PED diversion of the lesion. Via femoral access, a long 6-F Fubuki sheath (Asahi Intecc, Irvine, USA) with Sofia catheter (Micro-Vention, Tustin, USA) support and systemic heparinization (ACT >250 s) enabled deployment of a 5.0 × 25 mm Pipeline Flex (Medtronic Neurovascular, Irvine, USA) across the aneurysm neck. Immediate angiography showed intra-aneurysmal stasis while preserving parent-artery flow. At 12 months, she is asymptomatic with a 70% reduction in the contrast-opacified aneurysm component to 7 mm, and the contralateral small aneurysm remains stable.ConclusionFlow diversion with a PED provided an effective, artery-preserving solution for a mid-cervical ICA aneurysm in tortuous anatomy, achieving immediate flow stasis with parent-artery patency. At 12 months, the patient is asymptomatic with a contrast-opacified component reduced to 7 mm. This case supports using flow diversion for extracranial ICA aneurysms when anatomy is favorable, alongside careful antiplatelet therapy and planned imaging follow-up.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Successful obliteration of a wide-necked carotid terminus aneurysm with an eCLIPs flow diverting device: A case report and review of literature.SAGE open medical case reports · 2026
- Patient-Specific Hemodynamic and Angiographic Evaluation of a Novel Flow-Diverting Device for Intracranial Aneurysms.Bioengineering (Basel, Switzerland) · 2026
- Endoluminal Reconstruction of Complex Cervical Internal Carotid Artery Dissections Using the Surpass Elite Flow Diverter: A Technical Report.Cureus · 2026
- Multicenter experience of pipeline embolization device used in small caliber vessels (< 2 mm) for intracranial aneurysm treatment and mid-term resultsFrontiers in Neurology · 2026
- Giant cervical internal carotid artery aneurysm associated with multiple intra- and extracranial aneurysms: a case report.Frontiers in surgery · 2026
- Subtonsillar Approach to a Polylobulated Posterior Inferior Cerebellar Artery Aneurysm: A Case Illustration.2026