Application Value of Fluorescence Polarization Measurement in the Diagnosis of Brucellosis.
Huimei Bi, Lei Zou, Jingyao Liu, Qingfeng Gao, Ci Wang, Liping Hou, Gang Wang, Jinxia Gao
Department of Clinical Laboratory, Beidahuang Industry Group General Hospital, Harbin, China. · Department of Preventive Medicine, School of Public Health, Mudanjiang Medical University, Mudanjiang, China.
Key points
From the paper's conclusion- FPA is a highly accurate and independent diagnostic marker for brucellosis and supports its application in large-scale screening programs. However, the subgroup ROC has truncation bias, and the lipid interference inference remains unvalidated.
Abstract
OBJECTIVE: To evaluate the diagnostic efficacy of the fluorescence polarization assay (FPA) for detection of brucellosis. METHODS: A total of 1,080 clinically confirmed brucellosis patients and 1,518 nonbrucellosis controls were enrolled. Participants were classified based on clinical manifestations and laboratory diagnoses. Serum samples were analyzed using the Rose Bengal plate agglutination test (RBPT), serum agglutination test (SAT), FPA, and enzyme-linked immunosorbent assay (ELISA), followed by comparative analysis. The overall diagnostic sensitivity of the two-stage screening algorithm across the full cohort was further calculated. RESULTS: Multivariate logistic regression analysis identified FPA as an independent diagnostic predictor for brucellosis (Odds Ratio (OR) = 6.24, 95% Confidence Interval (CI): 5.18-7.51, p < 0.001). The area under the ROC curve (AUC) for FPA was 0.983 (95% CI: 0.978-0.987). At an optimal cutoff value of 81.5 millipolarization units (mP), FPA achieved a sensitivity of 93.80% and a specificity of 93.61%. Agreement analysis demonstrated high to perfect concordance between FPA and SAT (Kappa = 0.788), RBPT (Kappa = 0.875), and ELISA (Kappa = 0.752) (all p < 0.001). Using the 95th percentile of FPA values (P95 = 83 mP) as the mass screening warning threshold, samples were classified as negative (≤83 mP) or suspected positive (>83 mP). Among 976 suspected positive cases in the brucellosis group and 68 in the control group, secondary receiver operating characteristic (ROC) analysis yielded an AUC of 0.898 (95% CI: 0.861-0.936). The optimal cutoff value was 92.5 mP, with a sensitivity of 82.79% and a specificity of 94.12%. FPA values between 83 mP and 92.5 mP were defined as an equivocal zone; the total sensitivity of this two-step screening strategy was only 74.8%. CONCLUSION: FPA is a highly accurate and independent diagnostic marker for brucellosis and supports its application in large-scale screening programs. However, the subgroup ROC has truncation bias, and the lipid interference inference remains unvalidated.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fluorescence polarization serology for veterinary brucellosis: anti-O-polysaccharide antibody biology, assay comparability, and decision-rule validationFrontiers in Microbiology · 2026
- Disease Biomarker Detection Using Fluorescence Polarization Assays: Principles and Clinical Applications.Diagnostics (Basel, Switzerland) · 2026
- Evaluation of a fluorescence polarization assay using MAP whole-protein antigen for the detection of anti-Mycobacterium avium subsp. paratuberculosis antibodies in cattle and buffaloes.Tropical biomedicine · 2026
- Diagnostic test evaluation of four serological assays for Brucella antibody detection in Bactrian camels (Camelus bactrianus) in Inner Mongolia, China: A Bayesian latent class analysis.Preventive veterinary medicine · 2026
- CALLY Index and Inflammatory Parameters for Predicting Focal Involvement in Human Brucellosis: A Retrospective Cohort Study.Diagnostics (Basel, Switzerland) · 2026
- Bayesian latent class analysis for evaluating diagnostic performance of three serological tests of bovine brucellosis in Pakistan.Preventive veterinary medicine · 2026