Real-World Clinical Outcomes Following Initiation of the iLet® Bionic Pancreas in Youth with Type 1 Diabetes.
Elizabeth R Sullivan-Ingram, Ortal Resnick, Mary Margaret Barr, Ambika P Ashraf
Division of Pediatric Endocrinology and Diabetes, University of Alabama at Birmingham and Children's of Alabama, Birmingham, Alabama, USA.
Key points
From the paper's conclusion- In this real-world pediatric cohort, iLet initiation was associated with substantial glycemic improvement without increased hypoglycemia, particularly among participants with high baseline HbA1c. Favorable outcomes were observed among participants contributing paired 12-month data.
Abstract
BACKGROUND: The iLet® Bionic Pancreas replaces carbohydrate counting and manual bolus calculations with simplified qualitative meal announcements. Its performance among diverse patients with high baseline glycated hemoglobin (HbA1c) is not well characterized. METHODS: Retrospective, single-center cohort study of 71 patients aged 6-21 years with type 1 diabetes (T1D) who initiated the iLet Bionic Pancreas (2023-2025). Primary outcomes were changes in HbA1c and time in range (TIR; 70-180 mg/dL [3.9-10.0 mmol/L]) from baseline to 3 months. Secondary outcomes included glycemic metrics through 12 months, hypoglycemia, and meal-announcement behavior. RESULTS: Mean age was 13.2 ± 3.5 years; 40.8% Black and 38.0% Medicaid-insured. Baseline HbA1c was 9.4 ± 2.1% (79 ± 23 mmol/mol) and TIR was 30.1 ± 19.0%. At 3 months, HbA1c decreased by 1.8 ± 1.7% (-20 ± 19 mmol/mol) and TIR increased by 22.4 ± 22.5 percentage points (both P < 0.0001) without increased hypoglycemia. Improvements were greatest among participants with baseline HbA1c ≥ 9.5% (≥80 mmol/mol) (ΔHbA1c = -3.0% [-32 mmol/mol]; ΔTIR = +31.2 percentage points). Among participants with paired 12-month data, HbA1c decreased from 9.6%-7.6% and TIR increased from 27.7 to 55.8% (both P < 0.0001). Mean meal announcements were 2.9/d at 3 months and 2.1/d at 12 months (P = 0.722) and were not associated with HbA1c or TIR at 3 months. CONCLUSIONS: In this real-world pediatric cohort, iLet initiation was associated with substantial glycemic improvement without increased hypoglycemia, particularly among participants with high baseline HbA1c. Favorable outcomes were observed among participants contributing paired 12-month data.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early Initiation of Automated Insulin Delivery at Type 1 Diabetes Diagnosis in Children and Adolescents Is Associated with Improved OutcomesDiabetes Technology & Therapeutics · 2026
- Real-World Glycemic Outcomes of Open-Source Automated Insulin Delivery During 12 Months Among People With Type 1 Diabetes Across Age Groups.Diabetes, obesity & metabolism · 2026
- Automated Insulin Delivery Use Among Preschool-Age Children With Type 1 Diabetes: A T1D Exchange Multicenter AnalysisJournal of Diabetes Science and Technology · 2026
- Open-source automated insulin delivery shows comparable glycemic outcomes to a commercial hybrid closed-loop system in real-world type 1 pediatric diabetes care: a retrospective cohort study from British Columbia, Canada.Pediatric diabetes · 2026
- Real-World Use of Hybrid Closed-Loop System in Very Young Children with Type 1 Diabetes: Daily Glycemic Patterns Support Glycemic Improvements and Highlight Emerging Challenges for HypoglycemiaDiabetes Technology & Therapeutics · 2025
- Real-World Outcomes of Automated Insulin Delivery in Young People With Type 1 Diabetes: A Systematic Review and Meta-Analysis.Diabetes, obesity & metabolism · 2026