Reliability and accuracy of smartphone-based facial scanning: Validation with direct anthropometry.
Prakash C, Pradeep Kandikatla, Anoosha Manda, Praveen Kumar Varma, Nagisetti Hari Babu, Avichal Singh Sodhi
Department of Orthodontics, Vishnu Dental College, Bhimavaram, AP, India.
Key points
From the paper's conclusion- Following scale factor calibration, smartphone-based 3D facial scanning application demonstrate high reliability, precision, and clinically acceptable agreement with direct anthropometry. These applications offer a portable and cost-effective option for facial assessment in orthodontic practice, pending independent accuracy validation using a non-circular reference standard.
Abstract
OBJECTIVES: To evaluate the reliability and measurement agreement of two smartphone-based facial scanning applications-Qlone (iOS) and Magiscan (Android)-with direct anthropometry following scale factor calibration, and to assess intra- and inter-examiner reliability. METHODS: A total of 22 orthodontic patients were enrolled in this prospective study. Nine soft tissue landmarks (midsagittal and bilateral) were marked using 2.5 mm stickers and three vertical and six transverse linear distances were measured using digital vernier calliper (resolution 0.01 mm, accuracy ±0.02 mm) for direct anthropometry and MeshLab software following .obj export and scaling for both applications. Reliability was assessed in 10 randomly selected patients after 15 days. RESULTS: Repeated-measures ANOVA (F-statistic, 2 and 42 degrees of freedom) showed no statistically significant differences between Qlone, Magiscan, and direct anthropometry for 8/9 parameters (p range 0.165-0.988; η2p range 0.001-0.082). A statistically significant difference was found for Exo Left-N (p = 0.041; η2p = 0.141; mean difference 0.55 mm), not considered clinically significant. Bland-Altman analysis confirmed clinically acceptable agreement (mean bias ⩽ 0.55 mm across all comparisons). Intraclass correlation coefficients (two-way mixed model, absolute agreement) were excellent for all parameters (intra-examiner 0.998-1.000, inter-examiner 0.994-0.999), with relative TEM ⩽ 0.79% and reliability coefficient R ⩾ 0.994. CONCLUSION: Following scale factor calibration, smartphone-based 3D facial scanning application demonstrate high reliability, precision, and clinically acceptable agreement with direct anthropometry. These applications offer a portable and cost-effective option for facial assessment in orthodontic practice, pending independent accuracy validation using a non-circular reference standard.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Equivalence of linear facial measurements obtained from smartphone-based 3-dimensional facial scanners and professional extraoral scanners: A retrospective clinical study.The Journal of prosthetic dentistry · 2026
- Trueness and precision of smartphone-based 3D scan in the assessment of facial edema in orthognathic surgeryJournal of Oral Biology and Craniofacial Research · 2026
- Accuracy (trueness and precision) of two handheld scanners and a smartphone for three-dimensional facial scanning: An in vivo study.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Trueness and scanning time of smartphone-based photogrammetry applications: an in vitro comparative study.Journal of dentistry · 2026
- Evaluation of Four 3D Facial Scanning Technologies: From Photogrammetry to Structured-Light Systems in Clinical DentistryDentistry Journal · 2026
- Validation of Consumer-Grade 3D Scanners for Clinical Facial Reconstruction: Comparison with a Professional Structured-Light Reference System.Bioengineering (Basel, Switzerland) · 2026