Journal of orthodontics

Effect of PolyJet print orientation on the fit of thermoformed aligners: An in vitro scanning electron microscopy study.

Naveen K Subbaiah, Prabhat Kumar Chaudhari, Ritu Duggal, Vilas D Samrit

Division of Orthodontics and Dentofacial Deformities, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi, India.

Preclinical

Key points

From the paper's conclusion
  • SEM evaluation revealed that thermoformed aligners fabricated on the original dental models demonstrated a comparable fit on rapid-prototyped dental models, with no significant differences observed between models fabricated in horizontal or vertical three-dimensional printing orientations.

Abstract

AIM: The study aimed to compare the fit of thermoformed aligners fabricated on the original dental model over the corresponding dental models created using rapid-prototyping, in horizontal or vertical orientations using scanning electron microscopy (SEM). METHODS: This study involved scanning 10 dental models using a Maestro 3D Desktop Scanner. The 10 processed STL files were then additively manufactured into 20 models using a PolyJet printer, 10 models printed in horizontal or vertical orientations, respectively. Two thermoformed aligners using 0.75 mm Duron blanks were fabricated over each original dental model with a Biostar machine and were adapted over the corresponding additively manufactured models. Models manufactured in two different orientations along with aligners were sectioned on the upper and lower-central incisors, first premolars and first molars and were prepared for SEM evaluation. The difference in data between the two groups was determined using an unpaired t-test. RESULTS: The fit of aligners on additively manufactured dental models in vertical or horizontal orientations was generally comparable. Across all regions evaluated, the mean measured discrepancies ranged below 196.2 ± 44.32 µm, which falls within ranges previously reported in the literature as clinically acceptable for thermoformed aligners (117.76 ± 23.58-196.2 ± 44.32 µm). CONCLUSION: SEM evaluation revealed that thermoformed aligners fabricated on the original dental models demonstrated a comparable fit on rapid-prototyped dental models, with no significant differences observed between models fabricated in horizontal or vertical three-dimensional printing orientations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Effect of PolyJet print orientation on the fit of thermoformed aligners: An in vitro scanning electron microscopy study — Science Skim