Centiloid scale and whole-brain histogram analysis of amyloid PET: A multi-tracer comparison and establishment of a Centiloid-like scale.
Ryo Yamakuni, Yasuhiro Abe, Shinya Seino, Hironobu Ishikawa, Naoyuki Ukon, Tensho Yamao, Takeyasu Kakamu, Hirofumi Sekino,
Department of Radiology and Nuclear Medicine, School of Medicine, Fukushima Medical University, Fukushima, Japan. · Department of Radiology, Fukushima Medical University Hospital, Fukushima, Japan.
Key points
From the paper's conclusion- BackgroundGlobal Alzheimer's Association Interactive Network (GAAIN) introduced the Centiloid (CL) scale as a standardized amyloid quantitative metric.ObjectiveTo establish reference values for MRI-based whole-brain histogram analysis (WBHA) and evaluate the correlations between WBHA parameters and the CL scale within the GAAIN multi-tracer dataset.MethodsMRI and amyloid PET images were obtained f
Abstract
BackgroundGlobal Alzheimer's Association Interactive Network (GAAIN) introduced the Centiloid (CL) scale as a standardized amyloid quantitative metric.ObjectiveTo establish reference values for MRI-based whole-brain histogram analysis (WBHA) and evaluate the correlations between WBHA parameters and the CL scale within the GAAIN multi-tracer dataset.MethodsMRI and amyloid PET images were obtained from datasets curated for CL calibration. For WBHA, brain extraction was performed using structural MRI. Skewness and mode-to-mean ratio (MMR) were subsequently derived from the brain-extracted PET images. Furthermore, a top 20% Map was generated from these images and segmented into gray (GM) and white matter (WM) voxels to calculate the GW (GM/WM)-ratio. Precalculated CL values were retrieved from the database for comparison.ResultsStrong correlations were observed between the CL values and WBHA parameters. CL significantly correlated with the top 20% GW-ratio (r = 0.7582-0.9460), whereas skewness exhibited moderate to strong correlations (r = -0.7559-0.9463). However, MMR showed weaker correlations (r = 0.4391-0.8856). Receiver operating characteristic analysis for distinguishing Aβ-positive from Aβ-negative cases in the 11C-PiB-only dataset revealed that the top 20% GW-ratio yielded an area under the curve (AUC) of 1.0000, identical to that of the CL scale. AUCs for skewness (0.9752) and MMR (0.8869) were lower. Using the CL methodology, formulas were established to transform the GW-ratio into a 0-100 scale, designated as the Centi-GW-Index.ConclusionsThe WBHA provides a unique framework and alternative to the CL approach for quantifying brain amyloid.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Centiloid Calibration and Application of MUSE-Based Amyloid PET Quantification for Florbetapir (AV-45)medRxiv · 2026
- Quantitative Amyloid Brain Imaging: A Literature Review of the Centiloid Scale in Alzheimer Disease EvaluationJournal of Nuclear Medicine Technology · 2026
- From image reconstruction to clinical prognosis: A comprehensive analysis of centiloid-based amyloid PET assessmentEuropean Journal of Nuclear Medicine and Molecular Imaging · 2026
- Centiloids in Amyloid PET: A Practical Guide to Quantitation InterpretationJournal of Nuclear Medicine Technology · 2026
- Quantification of global gray matter amyloid-β plaque from 18F-Florbetaben PET/MRI and correlation to BAPL score in patients with cognitive impairment.Alzheimer's & dementia (Amsterdam, Netherlands) · 2026
- Harmonizing amyloid PET tracers at the local level: evaluation of regional Centiloid equationsbioRxiv · 2026