Journal of Alzheimer's disease : JAD

Centiloid scale and whole-brain histogram analysis of amyloid PET: A multi-tracer comparison and establishment of a Centiloid-like scale.

Ryo Yamakuni, Yasuhiro Abe, Shinya Seino, Hironobu Ishikawa, Naoyuki Ukon, Tensho Yamao, Takeyasu Kakamu, Hirofumi Sekino,

Department of Radiology and Nuclear Medicine, School of Medicine, Fukushima Medical University, Fukushima, Japan. · Department of Radiology, Fukushima Medical University Hospital, Fukushima, Japan.

Key points

From the paper's conclusion
  • BackgroundGlobal Alzheimer's Association Interactive Network (GAAIN) introduced the Centiloid (CL) scale as a standardized amyloid quantitative metric.ObjectiveTo establish reference values for MRI-based whole-brain histogram analysis (WBHA) and evaluate the correlations between WBHA parameters and the CL scale within the GAAIN multi-tracer dataset.MethodsMRI and amyloid PET images were obtained f

Abstract

BackgroundGlobal Alzheimer's Association Interactive Network (GAAIN) introduced the Centiloid (CL) scale as a standardized amyloid quantitative metric.ObjectiveTo establish reference values for MRI-based whole-brain histogram analysis (WBHA) and evaluate the correlations between WBHA parameters and the CL scale within the GAAIN multi-tracer dataset.MethodsMRI and amyloid PET images were obtained from datasets curated for CL calibration. For WBHA, brain extraction was performed using structural MRI. Skewness and mode-to-mean ratio (MMR) were subsequently derived from the brain-extracted PET images. Furthermore, a top 20% Map was generated from these images and segmented into gray (GM) and white matter (WM) voxels to calculate the GW (GM/WM)-ratio. Precalculated CL values were retrieved from the database for comparison.ResultsStrong correlations were observed between the CL values and WBHA parameters. CL significantly correlated with the top 20% GW-ratio (r = 0.7582-0.9460), whereas skewness exhibited moderate to strong correlations (r = -0.7559-0.9463). However, MMR showed weaker correlations (r = 0.4391-0.8856). Receiver operating characteristic analysis for distinguishing Aβ-positive from Aβ-negative cases in the 11C-PiB-only dataset revealed that the top 20% GW-ratio yielded an area under the curve (AUC) of 1.0000, identical to that of the CL scale. AUCs for skewness (0.9752) and MMR (0.8869) were lower. Using the CL methodology, formulas were established to transform the GW-ratio into a 0-100 scale, designated as the Centi-GW-Index.ConclusionsThe WBHA provides a unique framework and alternative to the CL approach for quantifying brain amyloid.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers