Tobacco use insights

Monitoring Indoor PM2.5 Concentrations in Food, Beverage, and Entertainment Venues in Vietnam: Implications for Smoke-Free Policy Implementation.

Thao Nguyen Thi Bich, Tan Luong Minh, Huong Le Thi Thanh, Anh Nguyen Quynh, Trang Phan Thi Thu, Mai Tran Thi Hoa, Minh Dao Le Hoang, Huyen Doan Thi Thu,

Faculty of Environmental and Occupational Health, Hanoi University of Public Health, Hanoi, Vietnam. · Campaign for Tobacco-Free Kids, Hanoi, Vietnam.

Observational

Key points

From the paper's conclusion
  • Our findings suggest that DSAs/DSRs do not adequately protect patrons and workers from SHS exposure, as smoke leakage into adjacent smoke-free areas. The current allowance for DSAs undermines the overall goal of creating comprehensive smoke-free public environments. To ensure adequate health protection, Vietnam should adopt 100% smoke-free indoor environments.

Abstract

BACKGROUND: Exposure to second-hand smoke (SHS) is a critical public health issue linked to severe respiratory and cardiovascular diseases. In Vietnam, the 2013 Law on Prevention and Control of Tobacco Harms permits designated smoking areas (DSAs) in certain hospitality and entertainment venues. Vietnam plans to revise the Law in 2026, providing an important opportunity to review the effectiveness of current smoke-free policies. This study compares indoor PM2.5 concentrations across venues with different smoke-free to evaluate the effectiveness of these partial restrictions. METHODS: A cross-sectional study was conducted across 78 venues (cafés, restaurants, karaoke lounges, and bars) in Hanoi, Bac Ninh, and Hoi An in 2025. PM2.5 concentrations were logged every 10 seconds for 60 minutes during peak business hours using IQAir-AirVisual Pro monitors. Venues were categorized as 100% smoke-free, fully smoking-permitted, and those with a DSA. RESULTS: The overall geometric mean (GM) PM2.5 concentration was 41.58 µg/m3, with median was 43.09 µg/m3. Smoke-free venues recorded the lowest levels (GM: 16.98 µg/m3; median: 19.83 µg/m3), while venues with DSAs (GM: 46.61 µg/m3, median: 44.98 µg/m3) and smoking-permitted venues (GM: 67.26 µg/m3, median: 61.06 µg/m3) were significantly higher (p<0.001). PM2.5 levels in venues with DSA were not statistically different from those where smoking was fully permitted (p=0.285), including in settings with high-risk of SHS exposure such as bars and karaoke lounges (p=0.229). Approximately 68.9% of surveyed cafés and restaurants were in violation of current regulations. The number of lit cigarettes was strongly correlated with PM2.5 levels (r=0.63; p<0.001). CONCLUSION: Our findings suggest that DSAs/DSRs do not adequately protect patrons and workers from SHS exposure, as smoke leakage into adjacent smoke-free areas. The current allowance for DSAs undermines the overall goal of creating comprehensive smoke-free public environments. To ensure adequate health protection, Vietnam should adopt 100% smoke-free indoor environments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Monitoring Indoor PM2.5 Concentrations in Food, Beverage, and Entertainment Venues in Vietnam: Implications for Smoke-Free Policy Implementation — Science Skim