Evaluation of a porcine tissue-based simulator for teaching ultrasound-guided PICC placement.
Lei Deng, Jiao He, Li Gao, Qin Guo, Ling Guo
School of Nursing, Chengdu Medical College, Chengdu, Sichuan, China. · Sichuan Cancer Hospital and Research Institute, Chengdu, Sichuan, China.
Key points
From the paper's conclusion- A porcine tissue-based ultrasound-capable simulator may be a feasible and accessible tool for early ultrasound-guided PICC training and was associated with better early performance in selected probe-handling and puncture behaviors during the first clinical case after training. These findings should be interpreted in light of the nonrandomized, time-based cohort design and require further validation.
Abstract
BACKGROUND: Ultrasound-guided peripherally inserted central catheter (PICC) placement requires stable probe handling and continuous needle-tip tracking, yet novice nurses have limited opportunities for repeated clinical practice. OBJECTIVE: This study aimed to evaluate the association between porcine tissue-based simulation training and early ultrasound-guided PICC placement performance among trainees. METHODS: This quasi-experimental study enrolled 216 infusion-therapy nurse trainees in Sichuan, China (2018-2021). Trainees were assigned by training period to a porcine tissue simulator group (n = 115) or a traditional arm-model group (n = 101). In each trainee's first clinical PICC after training, two preceptors assessed probe handling (vein identification within 10 s; maintenance of vessel centering), puncture behaviors (needle advancement aligned with the vertical centerline of the target vein on the ultrasound short-axis view; intraluminal needle-tip centering; continuous needle-tip visualization), and procedural familiarity scores. RESULTS: Vein identification within 10 s was similar between groups (93.0% vs 90.1%, p = 0.435). Compared with the arm-model group, the simulator group more often maintained vessel centering (90.4% vs 70.3%, p < 0.001), advanced the needle in alignment with the target vein (91.3% vs 69.3%, p < 0.001), achieved intraluminal needle-tip centering (87.0% vs 60.4%, p < 0.001), and maintained continuous needle-tip visualization (74.8% vs 50.5%, p < 0.001). Procedural familiarity scores were higher in the simulator group (94.3 ± 1.6 vs 93.4 ± 1.6, p < 0.001). CONCLUSIONS: A porcine tissue-based ultrasound-capable simulator may be a feasible and accessible tool for early ultrasound-guided PICC training and was associated with better early performance in selected probe-handling and puncture behaviors during the first clinical case after training. These findings should be interpreted in light of the nonrandomized, time-based cohort design and require further validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rapid skill acquisition through task-specific ultrasound training for peripheral cannulation in medical students.BMC medical education · 2026
- How to perform ultrasound-guided cannulation in adults.Nursing standard (Royal College of Nursing (Great Britain) : 1987) · 2026
- Ultrasound-guided versus open surgical central venous access in children: A systematic review.JPEN. Journal of parenteral and enteral nutrition · 2026
- Training in Ultrasound-Guided Technique for Peripheral Venous Cannulation in Nurses: Scoping ReviewClinics and Practice · 2026
- Ultrasound-Guided Vascular Access Training: A Single-Center Experience Using Gelatin-Based Simulation Models.Cureus · 2026
- A needle-mounted guide for improving needle visualization during ultrasound-guided needle insertion: a simulation study in novice operators.JA clinical reports · 2026