EXPRESS: Agreement between point-of-care and external reference laboratory RT-qPCR testing for feline coronavirus in cats with suspected feline infectious peritonitis.
Marieke Knies, Nikki Hofman, Johanna Jackson-Onis, Els M Broens, Erik Teske
AniCura Specialist Referral Centre Haaglanden, The Netherlands. · Department of Biomolecular Health Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands.
Key points
From the paper's conclusion- One hundred cats were included (effusions n = 62, FNAs n = 38). Overall agreement between assays was substantial (κ = 0.73), with near-perfect concordance for effusions (κ = 0.81) and lower agreement for FNAs (κ = 0.61). Relative sensitivity was highest in effusions (98.1% point-of-care, 92.3% external) and lower in FNAs (63.3-64.5%), with negative predictive values showing similar trends. Cp values were moderately correlated between assays, with minor mean differences (~1 cycle).
Abstract
OBJECTIVES: To evaluate the agreement of a commercially available point-of-care FCoV RT-qPCR assay and external laboratories RT-qPCR testing in cats with effusive and non-effusive FIP, and in cats with other diseases presenting with similar clinical signs. METHODS: Client-owned cats suspected of FIP were enrolled with owner consent. Effusions and ultrasound-guided fine-needle aspirates (FNAs) from liver, spleen, or mesenteric lymph nodes were collected, split, and analysed using both a point-of-care RT-qPCR and an external laboratory RT-qPCR. FIP was diagnosed based on AAFP/EveryCat guidelines. Sensitivity and negative predictive values were calculated, agreement assessed with Cohen's kappa, paired differences tested with McNemar's test, and correlation of crossing point (Cp) values analysed using Pearson's coefficient and paired t-tests. RESULTS: One hundred cats were included (effusions n = 62, FNAs n = 38). Overall agreement between assays was substantial (κ = 0.73), with near-perfect concordance for effusions (κ = 0.81) and lower agreement for FNAs (κ = 0.61). Relative sensitivity was highest in effusions (98.1% point-of-care, 92.3% external) and lower in FNAs (63.3-64.5%), with negative predictive values showing similar trends. Cp values were moderately correlated between assays, with minor mean differences (~1 cycle). CONCLUSION AND RELEVANCE: The point-of-care FCoV RT-qPCR assay is a practical and reliable tool and shows very good agreement with external reference laboratory RT-qPCR testing. FNAs remain useful when effusions are unavailable but carry higher risk of false negatives likely due to low viral loads and heterogeneous distribution. Point-of-care testing offers rapid turnaround, supporting timely clinical decision-making, but results must be interpreted alongside clinical presentation and other diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rethinking Feline Infectious Peritonitis Diagnosis: The FIP Predictive Score Within an Effusion-Based Diagnostic Algorithm—A Pilot StudyPathogens · 2026
- Combined molecular and clinicopathologic characterization of feline coronavirus infection in cats from a multicat shelterJurnal Medik Veteriner · 2026
- Beyond Modified Transudates: Diagnostic Performance of the Feline Infectious Peritonitis Effusion Index on the Sysmex XN-1000V.Pathogens (Basel, Switzerland) · 2026
- Pericardial effusion as a manifestation of feline infectious peritonitis.Journal of veterinary research · 2026
- De Ritis Ratio and L-FABP as Supportive Biomarkers of Hepatic Involvement in Cats with Effusive FIP.Topics in companion animal medicine · 2026
- Double‐Antibody Sandwich Enzyme‐Linked Immunosorbent Assay for Detecting Feline Coronavirus InfectionVeterinary Medicine and Science · 2026