Effect of Rescuer Position on Chest Compression Quality and Rescuer Stability during CPR on a Sloped Surface: A Simulation Study.
Eva Dolenc Šparovec, Jakob Praznik, Žiga Metelko, Damjan Slabe
Faculty of Health Sciences, University of Ljubljana, Ljubljana, Slovenia. · Department of Sanitary Engineering, Public Medical Centre Kranj, Emergency Medical Service, Kranj, Slovenia.
Key points
From the paper's conclusion- This study aimed to evaluate the impact of rescuer positioning on CC quality during CPR on a slope.MethodsA repeated-measures simulation study was conducted with 50 basic life support-trained volunteers.
Abstract
IntroductionHigh-quality chest compressions (CCs) are essential for survival after cardiac arrest. Current cardiopulmonary resuscitation (CPR) guidelines recommend performing CCs on a firm and flat surface; however, cardiac arrest may also occur in austere environments such as mountainous or sloped terrain where such conditions cannot be achieved. This study aimed to evaluate the impact of rescuer positioning on CC quality during CPR on a slope.MethodsA repeated-measures simulation study was conducted with 50 basic life support-trained volunteers. Participants performed uninterrupted CCs for 2 min in 3 different positions relative to the victim on a natural slope: uphill, downhill, and parallel. CC quality was assessed using a Resusci Anne QCPR manikin and the Laerdal QCPR application.ResultsRescuer position significantly affected CC quality and subjective ratings (P < 0.05). The downhill position achieved the highest proportion of time within the recommended compression rate range (median 90% vs 30% in the uphill position; P < 0.001) and deeper compressions (71 mm vs 67 mm; P < 0.001). In contrast, the uphill position was associated with higher compression rates and reduced chest recoil quality. Subjective assessments also differed significantly between positions. Compared with the downhill position, the uphill position was associated with greater physical demand, poorer stability, increased hand slipping, and greater fear of falling (all P < 0.001).ConclusionsRescuer position significantly influences CC quality and perceived rescuer safety during CCs on sloped terrain. Performing CCs from a downhill position may improve CC performance in austere and mountainous environments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mechanical Versus Manual CPR as Performed in a Complex Ski Patrol Environment: A Prospective, Crossover Study.Wilderness & environmental medicine · 2026
- Association of Chest Compression Depth, Rate, and Spring Resistance with "Quality CardioPulmonary Resuscitation" (QCPR) Scores in a Manikin Model.Journal of medical systems · 2026
- "Resuscitation on the go"- Musculoskeletal discomfort, CPR quality and provider experiences in a transit ambulance setting: A simulated, mixed-methods study.International journal of emergency medicine · 2026
- A randomised controlled trial of defibrillation with manual pressure augmentation during out-of-hospital cardiac arrestResuscitation · 2026
- Mechanical limitation of compression depth in a common CPR training manikin.Advances in simulation (London, England) · 2026
- Expert‐Selected Camera Viewpoints for Dispatcher‐Assisted BLS: A Delphi Consensus StudyJournal of Evaluation in Clinical Practice · 2026