Effects of Metal Climbing Gear and Lightning Safety Position During Simulated Lightning.
Mathias Maurer, Wolfgang Lederer, Benjamin Treichl, Markus Isser, Sandra Bauchinger, Stephan Pack
TINETZ-Tiroler Netze GmbH, Thaur, Austria. · Department of Anesthesiology and Critical Care Medicine, Medical University of Innsbruck, Innsbruck, Austria.
Key points
From the paper's conclusion- When the metal gear was in contact with the ground, upward leaders were seen to occur and downward discharges to even hit the head of the subject.ConclusionsThe findings of this experimental study indicate that unless grounded, metal gear on a climbing harness does not increase the risk of a direct lightning impact.
Abstract
IntroductionWhen trapped in a climbing route during a thunderstorm, it is generally recommended that climbers should maintain a maximum distance from rock formations and water accumulations. It is common practice for climbers to untie themselves from the rope and deposit metal equipment a few meters away.MethodsIn an experimental study, the formation of upward leaders from metal gear attached to a climbing harness and the number of lightning strikes to rope, metal gear, and subject were evaluated. A lightning impulse generator was used to simulate high-voltage discharges of up to 2500 kV.ResultsWhen the subject was suspended from a conducting rope, no upward leaders were observed, and no lightning strikes hit the subject. Ungrounded metal gear kept on the climbing harness did not increase the risk of a direct impact, even in the presence of upward leaders. When the metal gear was in contact with the ground, upward leaders were seen to occur and downward discharges to even hit the head of the subject.ConclusionsThe findings of this experimental study indicate that unless grounded, metal gear on a climbing harness does not increase the risk of a direct lightning impact. The authors recommend that when caught in a thunderstorm, climbers should refrain from unnecessary touching of the rope. Furthermore, climbers should ensure that they do not untie from the rope.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Full-process evaluation of lightning protection for multi-circuit 10 kV distribution linesJournal of Physics: Conference Series · 2026
- Spatiotemporal dynamic lightning damage risk assessment for high-altitude distribution lines considering seasonal surface evolution and time-varying lightning withstand capabilityFrontiers in Energy Research · 2026
- Straight-Arm Hang Endurance and Grip Performance While Wearing Winter Gloves: Implications for Chairlift RescueApplied Sciences · 2026
- Schrittspannungen bei Blitzeinschlägen in PV-Freiflächenanlagen im nationalen Kontexte+i Elektrotechnik und Informationstechnik · 2026
- Transition-Phase Injuries and Wilderness EMS Operations During a Mountain Paragliding Festival: A Brief Report.Wilderness & environmental medicine · 2026
- Design and experimental validation of an active-clamping anti-slip trolley device for high-voltage transmission linesJournal of Physics: Conference Series · 2026