Development and validation of Oncalyx, a digital tool for chemotherapy dose calculation: Content validity, computational accuracy and usability.
Ganesh Bh, Praneet Singh Bedi, Alim Shaikh, Naureen Imran
School of Dentistry, Dr. D. Y. Patil Deemed to be University, Navi Mumbai, Maharashtra, India. · School of Medicine, Dr. D. Y. Patil Deemed to be University, Navi Mumbai, Maharashtra, India.
Key points
From the paper's conclusion- Unaided task completion was 98.3%, without critical errors (mean SEQ 6.62/7; SUS 89.0, 95% CI 84.4-93.6).ConclusionsIn this preliminary evaluation, Oncalyx showed excellent content validity, computational agreement and usability.
Abstract
BackgroundChemotherapy dosing integrates body size, organ function, regimen rules, dose banding and cumulative limits. Manual calculations and unvalidated calculators may introduce errors, while few tools provide transparent calculations tailored to local clinical practice.ObjectiveTo develop Oncalyx and evaluate its content validity, computational accuracy and usability.MethodsA web-based, server-side engine incorporated 156 version-controlled rules covering 26 regimens and organ-function adjustments for 25 drugs, derived from guidelines and pivotal trials. Ten oncology professionals (four oncologists, three pharmacists, three nurses) evaluated 21 content-validity items. Independently calculated reference doses for 30 synthetic cases spanning nine clinical profiles (65 drug lines) were compared with Oncalyx outputs at ±1% and ±5% tolerances, using Bland-Altman analysis and Lin's concordance correlation coefficient (CCC). Ninety-two automated test vectors were executed. Usability was evaluated through six observed tasks, the Single Ease Question (SEQ) and System Usability Scale (SUS).ResultsAll items achieved item-level content validity indices ≥0.90 (S-CVI/Ave 0.98; S-CVI/UA 0.81); 99.0% of correctness ratings were positive. Body surface area and creatinine clearance agreed within ±1% across all cases. Among 64 evaluable drug lines, 62 (96.9%) agreed within ±1% and 63 (98.4%) within ±5% (bias -0.02%; CCC 0.999). The largest discrepancy (-19.9%) reflected a reference error, not an Oncalyx error. All automated tests passed. Unaided task completion was 98.3%, without critical errors (mean SEQ 6.62/7; SUS 89.0, 95% CI 84.4-93.6).ConclusionsIn this preliminary evaluation, Oncalyx showed excellent content validity, computational agreement and usability. Transparent calculations, unit checks and version-stamped dose sheets facilitate independent verification; larger, multicentre, real-world evaluation is needed before wider use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- CUI ‐ MET : A Clinical Utility Index Based Analysis and Decision Framework for Dose Optimization in Multiple‐Dose, Multiple‐Outcome Randomized TrialsPharmaceutical Statistics · 2026
- Development and implementation of a standardized audit tool for cytotoxic drug preparation practices in oncology.Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners · 2026
- AI-Based Cancer Drug Response Prediction: A Machine Learning Ensemble for Lung Cancer Pharmacogenomic ClassificationInternational Journal of Scientific Research in Computer Science Engineering and Information Technology · 2026
- Qualitative and Quantitative Assessment of Pharmacotherapy in a Medical Organization: A Pilot StudySafety and Risk of Pharmacotherapy · 2026
- ClinDataBench: Benchmarking Large Language Model Agents in Clinical Trial Analysis Dataset ConstructionmedRxiv · 2026
- Enabling Just-in-Time Clinical Oncology Analysis With Large Language Models: Feasibility and Validation Study Using Unstructured Synthetic DataJMIR Medical Informatics · 2025