Fibrinolytic Response to Protein C Zymogen and Plasma in Sepsis-Associated Purpura Fulminans: A Case Series of Nine Consecutive Patients.
Andrea Meli, Tiziana Marchesi, Ivan Silvestri, Alessio Caccioppola, Cristina Novembrino, Giacomo Grasselli, Mauro Panigada
Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy. · Pediatric Intensive Care Unit, Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
Key points
From the paper's conclusion- We retrospectively analyzed nine patients (six adults, three children) admitted to our intensive care units between 2017 and 2025 with PF associated with septic shock, treated with PC zymogen concentrate and fresh frozen plasma (FFP).
Abstract
Purpura fulminans (PF) is a rare and life-threatening manifestation of disseminated intravascular coagulation, leading to multiorgan failure. Protein C (PC) zymogen supplementation has a strong pathophysiological rationale, but its effects on the viscoelastic fibrinolytic profile have not been described. We retrospectively analyzed nine patients (six adults, three children) admitted to our intensive care units between 2017 and 2025 with PF associated with septic shock, treated with PC zymogen concentrate and fresh frozen plasma (FFP). In the six adults, PC and fibrinolysis were measured before and a median of 13 hours after the PC loading dose, fibrinolysis with modified viscoelastic hemostatic assays (urokinase-modified thromboelastography [UK-TEG] in three, tissue plasminogen activator test [TPA-test, ClotPro] in three). Median (interquartile range) PC rose from 23 (10-31)% to 102 (63-137)% and Lysis, the percentage of clot lysis at the modified assays, from 15 (0-47)% to 78 (60-100)%. All six patients had fibrinolysis resistance before treatment. Lysis increased in five and returned within the reference interval in one; in the three TPA-test patients, lysis time became measurable after treatment but remained above 300 s. Three patients died and four required surgery for necrotic skin or soft tissue lesions. PC and FFP administration was followed by a partial recovery of the fibrinolytic response, which cannot be attributed to PC alone, since plasma was given at the same time. Modified viscoelastic assays may help monitor the response to PC and plasma therapy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fibrinolysis resistance in sepsis assessed by serial beside viscoelastometry is associated with plasma protein profiles and organ-failure severity: a prospective observational studymedRxiv · 2026
- Exploratory associations between inflammatory indices, timing of plasma therapy, and outcomes in adult purpura fulminans: a retrospective case seriesFrontiers in Medicine · 2026
- Investigating Fibrinolysis Resistance in Sepsis Using High‐Multiplex Plasma Proteomics: A Statistical Analysis PlanActa Anaesthesiologica Scandinavica · 2026
- Modelled mortality benefits of reducing fibrinolysis resistance in sepsis: integrating observational and ex vivo datamedRxiv · 2026
- Rotational Thromboelastometry (ROTEM)-Guided Assessment of Hemorrhagic Disseminated Intravascular Coagulation in Septic Shock: A Case Report of Purpura Fulminans and Multiorgan Failure.Cureus · 2026
- Trajectories of Coagulation-Fibrinolysis Balance Reveal Hemostatic Heterogeneity in Sepsis: Derivation and Multicenter Validation.Thrombosis and haemostasis · 2026