The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association

Impact of Scar Contracture on Miniscrew-Assisted Rapid Palatal Expander Efficacy in Unilateral Cleft Lip, Alveolus, and Palate: A Finite Element Analysis.

Rizqi Nurarifka Walupi, Cendrawasih Andusyana Farmasyanti, Sri Suparwitri, Anne Marie Kuijpers-Jagtman, Ananto Ali Alhasyimi

Department of Orthodontics, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta, Indonesia.

Computational

Key points

From the paper's conclusion
  • ObjectiveThis study investigates the impact of scar contracture on displacement of the maxillary segments during miniscrew-assisted rapid palatal expansion (MARPE) in unilateral cleft lip, alveolus, and palate (UCLAP) using finite element analysis (FEA).MethodsA finite element model was constructed from a 3-dimensional maxilla model derived from a CT scan of a patient with UCLAP, incorporating sca

Abstract

ObjectiveThis study investigates the impact of scar contracture on displacement of the maxillary segments during miniscrew-assisted rapid palatal expansion (MARPE) in unilateral cleft lip, alveolus, and palate (UCLAP) using finite element analysis (FEA).MethodsA finite element model was constructed from a 3-dimensional maxilla model derived from a CT scan of a patient with UCLAP, incorporating scar tissue along with a 3-dimensional MARPE model. Simulations were conducted with (MARPE + s) and without (MARPE - s) scar tissue forces from the palatal tissue and upper lip, with the same MARPE expansion force applied in both conditions. Displacement was observed at 16 reference points on the palate and teeth along the x- (transverse), y- (vertical), and z- (sagittal) axes.ResultsBoth simulations exhibited lateral, inferior, and anterior displacement along the x-, y-, and z-axes. Notably, the minor segment showed slightly greater displacement than the major segment along the x- and z-axes, whereas the major segment showed slightly greater displacement along the y-axis. Slightly lower displacement values were observed in the MARPE + s simulation compared with the MARPE - s simulation across all 3 axes.ConclusionsBoth simulations produced generally comparable displacement patterns, with only minimal reductions observed in the presence of scar tissue forces. These findings suggest that scar tissue may have only a limited biomechanical influence on MARPE expansion under the modeled conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers