Evaluating Patient Adherence to Cranial Orthosis Treatment Using Temperature Sensors and a Mobile Device Application.
Anna L Preisler, Jeffrey A Kasparek, Jerold N Luisi, Melody M Gordon, Jill L Findley, Werner Koele, Karl Strohmayer, Timothy R Littlefield
Cranial Technologies Inc., Tempe, AZ, USA. · SteadySense GmbH, Graz, Austria.
Key points
From the paper's conclusion- Overall, the recorded average daily wear was lower than the prescribed treatment protocol, underscoring a gap between recommended and actual adherence.
Abstract
ObjectiveTo evaluate the feasibility of using temperature sensors and a mobile app to objectively measure cranial remodeling orthosis (CRO) wear time, assess adherence to the prescribed 23 h per day wear schedule, and examine the relationship between wear time and treatment outcomes.DesignProspective, multisite cohort study.SettingSix Cranial Technologies clinical sites across Arizona.Patients/ParticipantsInfants aged 3 to 18 months treated with a CRO equipped with a temperature sensor. A total of 87 infants who received a sensor were eligible for wear time analysis, and of those, 78 completed treatment with exit 3-dimensional imaging.Main Outcome Measure(s)Daily CRO wear time was objectively measured by a temperature sensor recording at 15-min intervals and changes in cranial shape, including cranial vault asymmetry index (CVAI(S)) and cephalic index (CI) were measured.ResultsThe average daily wear time was 15.9 ± 6.1 h across all infants and 18.0 h among those who completed treatment. No sensor-related complications occurred. Greater wear time was significantly associated with greater reduction in CVAI(S), but not CI, likely due to the small number of infants with brachycephaly. Notably, older infants derived significantly more benefit from increased wear time than younger infants.ConclusionsMeasuring CRO adherence using a temperature sensor with a mobile application is feasible and did not produce any observed safety concerns. Overall, the recorded average daily wear was lower than the prescribed treatment protocol, underscoring a gap between recommended and actual adherence.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of Age on Success of 3D-Printed Cranial Remolding Orthoses for Deformational Head Shapes.Journal of clinical medicine · 2026
- Seasonal and Temporal Patterns of Brace-Wearing Behavior in Adolescent Idiopathic Scoliosis Assessed Using Objective Sensor Data.Medicina (Kaunas, Lithuania) · 2026
- Adherence and Radiological Outcomes in Braced Adolescents with Idiopathic Scoliosis: A Real-World Study Using Thermal SensorsJournal of Clinical Medicine · 2025
- Wear-time monitoring in functional orthodontic appliances does not enhance patient satisfaction and is not associated with improved treatment duration or occlusal outcomes: A randomized controlled trial.Journal of the World federation of orthodontists · 2026
- Objective assessment of wear time during orthodontic aligner therapy using microsensors: A randomized controlled trialAmerican Journal of Orthodontics and Dentofacial Orthopedics · 2026
- Diagnostic accuracy of a thermal microsensor for measuring wear time of removable extra-oral orthodontic appliances.Minerva dental and oral science · 2026