Current Clinical Practice and Barriers to Instrumented Gait Assessment in Stroke Rehabilitation: A Cross-Sectional Survey.
Sota Araki, Takaaki Ikeda, Masanori Wakida, Ryosuke Kitatani, Hiroki Kubo, Naomichi Mizuta, Masataka Yamamoto, Keita Honda,
Stroke Gait Disturbance Task Force, Strategic Problem-Solving Committee, Japanese Society of Neurological Physical Therapy. · Research Organization of Science and Technology, Ritsumeikan University, Kusatsu, Japan.
Key points
From the paper's conclusion- Instrumented gait assessment may address these limitations, but its routine use and implementation barriers remain unclear.ObjectivesTo investigate gait assessment practices and barriers to routine instrumented gait assessment among physiotherapists treating people with stroke.MethodsA web-based cross-sectional survey was conducted among members of the Japanese Society of Neurological Physical The
Abstract
BackgroundObservational gait analysis is widely used in stroke rehabilitation but may have limited objectivity and reproducibility. Instrumented gait assessment may address these limitations, but its routine use and implementation barriers remain unclear.ObjectivesTo investigate gait assessment practices and barriers to routine instrumented gait assessment among physiotherapists treating people with stroke.MethodsA web-based cross-sectional survey was conducted among members of the Japanese Society of Neurological Physical Therapy. Respondents reporting limitations in observational gait analysis completed additional questions on instrumented gait assessment. Logistic regression examined factors associated with perceived measurement time burden among device users.ResultsOf 329 respondents, 95.4% used standardized clinical gait assessments, and 81.8% perceived limitations in observational gait analysis. Although 91.2% recognized the need for instrumented gait assessment, only 39.8% of the 269 respondents completing the second-stage questions used it routinely. Of 162 non-users, 80.2% reported that relevant equipment was unavailable. Device users commonly reported excessive measurement time, high equipment costs, and difficulty interpreting results. Measurement time ≥20 min was associated with perceived measurement time burden (odds ratio 3.59, 95% confidence interval 1.04-12.46; p = 0.044). Automated analysis (95.5%) and usability regardless of location (83.6%) were frequently desired.ConclusionsInstrumented gait assessment was widely perceived as necessary, but routine use remained limited. Improving equipment access and developing time-efficient, portable systems with automated analysis and interpretation support may facilitate integration into routine stroke rehabilitation and sustained clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validity of Functional Performance Outcomes and Gait Metrics Measured by Smartphone Application in Patients with Chronic Stroke.Sensors (Basel, Switzerland) · 2026
- AI-Based Gait Analysis System for Rehabilitation: Usability Evaluation of Human-Technology InteractionJMIR Rehabilitation and Assistive Technologies · 2025
- Beyond Walking Speed: Estimating and Classifying Post-Stroke Gait Propulsion From Standardized Clinical Measures.medRxiv : the preprint server for health sciences · 2026
- A portable biomedical device for post-stroke spasticity assessment: preliminary validation studyResearch on Biomedical Engineering · 2026
- A normative torque-profile approach for quantifying elbow and wrist flexor hyper-resistance after stroke: a proof-of-principle studymedRxiv · 2026
- Objective Longitudinal Monitoring of Postural Stability and Gait During Neurorehabilitation: Clinical Application of Instrumented Posturography and Three-Dimensional Motion Analysis.Bioengineering (Basel, Switzerland) · 2026